SAMES KREMLIN
Page 6
Manual : 573.182.112
INSTALLATION
HA
HB
B
MP
S
A
AC
19
17
18
13
14
11
12
9
8
15
20
Interconnect hoses (18) and (17) between the pump and the AIRMIX ® gun :
The hose (18) should be static proof (green band). I.D. 7 mm / 9/32".
The hose (17) should be an AIRMIX ® one. I.D. 4,8 mm / 3/16" or 6,5 mm / 1/4".
Connect the pump air supply to the compressed air system with an hose - I.D. 10 mm / 3/8".
Nota : these hoses are not included in the equipment.
Choose an AIRMIX ® nozzle (size from 04 to 09 - refer to chart of nozzles in the gun instruction
manual) and install it on the gun (19).
The PU 2160F pump is fitted with an earth cable. Ground the pump.
Fill with 'T' lubricant or with the appropriate lubricant the BASE fluid section flange. Fill the cup to
the 3/4.
Unscrew the 2 air regulators (8 & 9), then supply the equipment with air (maximum P = 6 bar / 87
psi, clean air).
→
Do not install isolating valve on the CATA supply system
(between the tank and
the FLOWMAX
fluid section).
It will damage the bellows.
→
Do not install a system that will act as a non return valve.
→
You
must not
create an
overpressure
in the CATA system.
5. OPERATING
LABEL
The label sticked on the pump explains the 3 operating stages of the pump : PRIMING -
WORKING - FLUSHING.
The 3 operating stages are selected :
- working the manifold valve (11) (
→
index A on the label),
- operating one of the valves of the color changer (12) (
→
index B on the label),
- working the valve (20) located at the base and solvent suction (
→
index S on the label).