SAMES KREMLIN
- 1 -
N° : 578.166.110-UK-2203
CAUTION :
Before any action on the pump, shut off the compressed air supply and
depressurize the system.
The pump is manufactured under the ATEX agreement and can not be modified.
SAMES KREMLIN will not be held responsible for any failure to comply with that instruction.
Guards (air motor cover, coupling shields, housings …) have been designed for
safe use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
SUCTION VALVE (REFER TO DOC. 573.049.050)
Unscrew suction valve (16) - (If cylinder (2) remains attached to the suction valve, unscrew the
whole. Then, hold cylinder (2) by inserting a rod into the cylinder holes designed for this
purpose).
The ball (17) is secured on the valve (16) by means of a circlips (18).
Clean the parts.
Reinstall suction valve (16) and seal (19). Replace them if necessary.
CYLINDER
In order to make easier the disassembly, a hole is drilled in the cylinder (2) at each end.
In relation to the part which is unscrewed first, insert a rod into one of these holes to unscrew the
other part.
When reassembling be certain the two seals (19) are installed.
EXHAUST VALVE AND MOBILE PACKING
Unscrew cylinder (2) and pull it downwards.
Unscrew exhaust valve (6) by holding piston (3).
Remove ball (8) and mobile packing (cup seal ind. 7).
Clean the parts and reinstall them. Replace seals if necessary.