A 1
PTFE grease
PTFE grease (10 ml / 0.0026 US gal)
560.440.101
A 3
Vaseline
-
560.440.002
C 2
Low strength
- Anaerobic Adhesive
Loctite 222 (50 ml / 0.013 US gal)
554.180.010
Nota :
Do not unscrew the two fluid fittings P1 and P2.
CHANGING THE GUN
Shut off the air and material supplies of the gun. Depressurize the circuits.
Separate the gun from its support.
Install the new gun.
CARTRIDGE AND NEEDLE
Unscrew the cylinder (35) - (pay attention to the springs 33 and 34).
Hold the needle and piston assembly (11 and 29) and pull it backwards.
Put aside the aircap (1) and the nozzle (7).
Unscrew the screw (27) by 2 turns (leakage detector).
Introduce the screwdriver backwards instead of the needle and force or knock until the cartridge (20)
gets out frontwards from the gun body.
Clean carefully with solvent and blow with air.
Change the seals. Install new ones.
Introduce the new cartridge frontwards.
IMPORTANT : push the cartridge completely. It must be located at the end of the gun
body.
Tighten the leakage detector (27).
Reinstall the piston and needle assembly (29 and 11).
Install the springs (33 and 34).
Screw the cylinder (35).
Unscrew the needle stop (36), then reinstall the nozzle (7) and the aircap (1).
During the assembly of the gun, screw completely the indexed needle and check the
lining up of the 3 following elements : the mark done on the body, the 0 on the
indexing ring and the line on the stop.
If it not be so, unclip the disc located on the indexed stop and change it alining up the
line with the 0.