SAMES KREMLIN
- 6 -
N° : 578.096.120-UK-1912
INSTALLATION DIAGRAM
A
-
Explosive
area
area 1 (Z1)
or area 2
(Z2) :
spraybooth
B - Non
explosive
area
1 - Pump
2 - Airspray gun
3 - Fluid hose
4 - Antistatic air
hose
5 - Air regulator
The 1 m / 39.37" distance indicated in the diagram is given for information purposes
only and hold harmless to SAMES KREMLIN. The user is responsible for the extraction
and conditioning of the painting area where the equipment is used, for working
conditions (refer to EN 60079-10 standard).
The 1 m / 39.37" distance may be modified if trials carried out by the user deem this
necessary.
1 - By means of a grounded air hose, connect the gun to an air regulator that can supply at least 3 bar
/ 43.5 psi.
2 - By means of a fluid hose, connect the gun fluid fitting to the pump. Tighten firmly the fittings.
Nota : In some particular cases, if the air hose (4) is not conductive, the fluid hose (3) must
be conductive.
One of the 2 gun hoses (air or fluid) must be conductive.