SAMES KREMLIN
- 1 -
N° : 578.058.110-UK-1903
TROUBLE
CAUSE
SOLUTION
No fluid out of the gun
Tip is blocked
Shut off pressure on pump.
Depressurize the hoses.
Remove and clean spray tip and
filter.
Low flow rate
Filter is partially clogged
Spray fan is not uniform
Tip is partially clogged
Spray fan is not uniform
Air holes in air cap are partially
blocked
Remove and clean with solvent.
Blow all air holes clear with
compressed air.
Excessive fluid fog
Too much atomizing air
Reduce atomizing air with the air
regulator.
Pattern width narrows during
reversing phase of pump
Air trapped in the fluid circuit
Check connection and suction
hose quality.
Viscosity too high
Reduce viscosity.
Air cap becomes dirtly frequently
Too much air
Reduce air pressure.
Seat-holder leaking
Replace it.
Fluid seeping from the air holes
of the air cap
Defective tip seal
Replace it.
Retaining ring loose
Tighten it.
Fluid leak through leakage
detector
Cartridge worn
Replace cartridge.
No change in pattern width
Air leak in front of the gun
Replace air adjuster.