Doc.-ID: 131106-PT03BA-SS-ExCam miniZoom_en_rev.01, Seite 15 von 24
5.2.7
Tests prior to switching on voltage
Attention!
Prior to commissioning, all tests as indicated by the national regula-
tions have to be executed. In addition, it is mandatory that the proper
functioning of the operating device in accordance with this user man-
ual and all other applicable regulation has been executed.
Attention!
Incorrect installation and operation of the camera may lead to a loss of
warranty!
5.3
Step 3: Adjusting the picture
Adjustment and optimization of the camera picture such as angle of view, zoom, focus,
back light compensation, or IR cut filter are exclusively carried out electronically via the
camera’s control interface. Mechanical settings at the camera’s block module (Sony
FCB-IX11AP) are neither necessary nor allowed!
For example, control functions can either be operated manually by the means of a Con-
trol Board which has a serial interface (RS-422) and which supports the VISCA protocol
(Sony FCB-IX11AP) or interactively via the web interface of a video server (figure 5.8) or
the FCB Control Panel (figure 5.7). The transmission rate of the sending and the receiv-
ing end has to be synchronous (figure 5.6).
Figure 5.6 Setting the Baud-transmission rate