5.2
Step 2: Electrical connection
Attention!
The electrical connection of the equipment must be executed by quali-
fied personnel only!
Attention!
It is mandatory that the housing of the ExCam
®
Series has to be
grounded via a PE-connection!
Attention!
The minimum cable length of the connection line must not be less
than one meter! The connection cable has to be laid in a protected
manner!
Attention!
Please observe the national regulations regarding security, installa-
tion, and accident prevention (e.g. DIN EN 60079-14), as well as the
safety guidelines described in this user manual and the ATEX installa-
tion manual!
The ExCam
®
miniZoom is delivered with an electrical connection cable type SKAxx (Sys-
tem Kabel Analog). The maximum cable length is 200 m and can be determined individ-
ually to reflect the particular customer specifications. The minimum cable length is 1 me-
ter.
The ExCam
®
miniZoom is manufactured with a pigtail reflecting the desired cable length.
Any electrical work
inside the camera’s flameproof enclosure, done by the user, is prohib-
ited.
Depending on the model option, the ending of the camera’s cable connection is ei-
ther stripped and furnished with wire-end ferrules or furnished with a BNC connector.