Doc.-ID: 200917-PT08BA-ES-ExCam IPP1275_en_rev.00.docx, Page 14 of 28
The pin assignment of the SKD04-T.flex is executed in accordance with the standard
EIA/TIA-568B for 100BaseTX as follows:
Camera (Ex-d)
(T568B)
Colour
SKD04-T.flex
(IEC60757)
Plug-
contact
Cross-
sectional
surface
Comment
PE
Shield
Tx+
WH / OG
1
0,23 mm
2
Massivleiter
Tx-
OG
2
0,23 mm
2
Massivleiter
Rx+
WH / GN
3
0,23 mm
2
Massivleiter
Rx-
GN
4
0,23 mm
2
Massivleiter
(PoE +48 VDC)
WH / BU
5
0,23 mm
2
Massivleiter
(PoE +48 VDC)
BU
6
0,23 mm
2
Massivleiter
(PoE GND)
WH / BN
7
0,23 mm
2
Massivleiter
(PoE GND)
BN
8
0,23 mm
2
Massivleiter
GND/SHD
PE
PE
Table 5-2 Aderbelegung des RJ12 Steckers (SKD04-T.flex)
Particularly in EMC critical environments, it is necessary to make sure that the cable shield is
grounded on side of the terminal block
!
The maximum cable length between camera and Ex-e terminal box is 25 m.
5.2.3
Connection to an ExConnection Rail / Routing into Ex-d
For cameras with the model key T08-
…-TD, the Sensor Unit is already connected to an
ExConnection Rail. The Main Unit P12 MkII is then placed in the Ex-d housing.
Figure 5-5 ExCam IPP1275
ExConnection Rail