Doc.-ID: 220607-PT08BA-ES-ExCam IPM2036_en_rev.00.docx, Page 21 of 36
5.3.3
Appropriate cables & cable entries
An integral part of the device safety is the correct selection of the cables, wires and cable
entries.
Attention!
Cables and wires must comply with the requirements of the IEC 60079-
0/1/7 & 14.
Attention!
The supply line must have a sufficient cross-section. The cable pro-
tection must comply with national and international regulations.
For non-binding configuration and planning guidelines, please visit
our website:
Perhaps our video will help you: "Cables for flameproof devices in potentially explosive
atmospheres"
http://go.samcon.eu/video-cable-ex
Figure 5-10 Ex-d cable selection
Particularly for installations requiring a suitable barrier gland, make sure that you handle
them correctly and observe the rules and notes given in the respective mounting and as-
sembly instructions.