Installation
For commissioning and operating the camera, the relevant national regulations, as well
as the generally accepted rules of technology shall prevail. Before mounting the camera,
thoroughly check it for any transport damage, especially on the housing and cable. Instal-
lation, electrical connection and the first start must only be carried out by qualified spe-
cialists.
Work preparation:
Attention!
Prepare your work carefully and in accordance with the relevant
regulations.
Attention!
Depending on classification of hazard areas, it is imperative to obtain
a work approval first!
When you open the pressure-resistant enclosure under voltage, it is
absolutely necessary to prevent potentially explosive atmosphere!
To ensure the best image quality delivered by the network camera, plan the installation
site carefully (consider light conditions, object distance or size, angle and minimum object
distance to the focus).
Use appropriate tools and aids.
When working, ensure a safe stand.
Make sure that any static charge is avoided.
Attention!
Please observe the national security, installation and accident preven-
tion regulations (e.g. DIN EN 60079-14) and the safety instructions in
this User Manual, as well as the ones in the Installation Guidelines!
Attention!
Adhere to the provisions of the IECEx, ATEX and
EX installation instructions for mounting and starting up!
The ExCam
®
IPM2036 consists of a flame-proof camera housing (Ex-d) and, optionally
(models with a terminal box …-T), a terminal box of a high degree of safety (Ex-e). Both
units are connected via a 5 m cable. Mount the camera according to the desired field of
view. Install the terminal box so that a good accessibility is provided, in order to facilitate
electrical connection.