Doc.-ID: 220607-PT08BA-ES-ExCam IPM2036_en_rev.00.docx, Page 32 of 36
If it is not possible to assign the IP address, it might be necessary to
change the firewall settings!
The “AXIS IP Utility“ tool automatically recognizes all ExCam devices and visualises
them in the device list. It can also be used to manually assign a static IP address. For this
purpose, the ExCam IPM2036 network camera has to be installed in the same physical
network segment (physical subnet) as the computer on which the AXIS IP Utility is run-
ning. The network signature of ExCam IPM2036 is "AXIS M2036-LE" (see Figure 7-1).
MAC address and serial number for clear device identification are also detected and dis-
played.
Figure 7-1 Axis IP Utility
7.3
Password/ Identification
The following user name is set at the factory:
root
The following password is set at the factory:
root
8
Maintenance / Modification
The applicable regulations for the maintenance and servicing of electrical devices in po-
tentially explosive atmospheres must be adhered to.
The required maintenance intervals are specific to the individual devices. The operating
company has to determine these intervals depending on the application parameters. The
maintenance tasks especially include examination of parts on which the ignition protec-
tion depends (e.g., proper condition of the casing, seals and cable entry points). If
maintenance measures are necessary they have to be initiated and/or executed.
ExCam IPM2036