6. COMMISSIONING
The commissioning of a newly purchased bale wrapping machine should be performer under
the supervision of an experienced operator or a dealer’s service representive.
IMPORTANT:
Before commissioning, familiarize yourself with the following manual,
paying special attention to the fragments regarding the safety of the operator
and bystanders.
Before each start up of the wrapping machine, the control levers shall be installed in the
tractor’s cabin.
6.1. Commissioning of the counter
The wrap counter shall be installed in the tractor‘s cabin, connected to the revolution sensor
and attached to the electric power source using the power cable. The proper connection is signalled
by a blinking red light on the counter display. Press and hold the buton (activation symbol C).
Each activation of the counter is accompanied by the display test and power supply voltage
test. The display will show the indication 8888 and all decimal points and LEDs will light up,
additionally the sound signal will be activated.
Then, the power source voltage will be displayed e.g. U12.7, which denotes voltage of
12.7V.
Every other condition indicates that the counter is damaged.
Then the year of manufacture of the counter will be displayed e.g. 2011 and a yellow LED
will light up (1).Using the F2 button enter the year of manufacture of the wrapping machine
(between 2000 and 2099). Pass to setting the wrapping machine serial numer with F1. A flashing
LED (2) signals the option of setting the wrapping machine option. Enter the serial number pressing
and holding F2 button (range from 0000 to 9999). Check if the entered data is correct by pressing
the F1 button. It should display the year of manufacture and the wrapping machine serial number in
an alternate way.
If the entered data is correct, confirm using the on/C button by pressing and holding it for
about 10 seconds. The confirmation of the entered data will be signalled by a blinking red LED and
intermittent sound signal.
It is only possible to enter the year of manufacture and serial number once. After the
information is confirmed, it cannot be corrected. To stop the data entering procedure, disconnect the
counter from its power source. The wrap counter data cannot be erased and no changes can be