34
11.2 Error Message
Error
Description
Reaction, error remedy
001
Open door
Close door or remedy defect on door switch.
111
Probe cooking chamber 1
no signal
Operation stop!
113
Meat probe
no signal sensor 1
Warning! Remedy sensor interruption.
Meat probe operation is possible!
Reset: Autonomous when repaired.
114
Meat probe
no signal sensor 2
Warning! Remedy sensor interruption.
Meat probe operation is possible!
Reset: Autonomous when repaired.
115
Meat probe
no signal sensor 3
Warning! Remedy sensor interruption.
Meat probe operation is possible!
Reset: Autonomous when repaired.
116
Meat probe
no signal sensor 4
Warning! Remedy sensor interruption.
Meat probe operation is possible!
Reset: Autonomous when repaired.
117
Water vapour elimination
sensor, no signal
Warning! Remedy sensor interruption.
Operation with a defective sensor is possible!
212
Over temperature STB
cooking chamber or motor
safety MI released
Operation stop!
Customer service call!
311
No water pressure
Cooking operation: Warning / autoclean: Pause Open water
valve. Remedy too low customer-side water pressure.
Check the pressure switch for proper functioning.Attention!
The appliance pauses in autoclean!
The appliance can be
used without water in cookingoperation!
313
Hand shower off
Activate Hand shower in the Srvice
511
Control module
Warning!
PCB temperature above 65°C
Operation possibile, Customer service call!
512
Control module
Operation stop!
PCB temperature above 70°C
Customer service call!