20
Operating conditions
3.
Installation
3.1
Requirements of installation
Place the induction unit on to a flat surface.
Do not disturb the air flow in- and outlets.
The table must be able to carry min. 40 kg.
The switch must be easy accessible.
Installation ambience
3.2
Installation instructions
Please observe the following rules:
- Check and ensure that the supply voltage matches the
voltage given on the specification plate
- The electrical connections must satisfy local house
installation regulations. The valid, national and local
regulations of the electricity-supply inspection
authorities must be observed.
- This induction appliance is equipped with a mains
cable which can be connected with the necessary plug
to the socket. The connector must be easily accessible
to disconnect the unit from the net.
- When faulty-current circuit breakers are used, they
must be rated for a breaking current of 30mA or more.
- This induction unit is equipped with an internal air
cooling system. Make sure that the air supply and air
exhaust are not blocked (wall, fabric etc)
- The induction unit is disposing of a removable fat filter.
Prevent hot- or unctuous air to be sucked into the unit.
- Do not set an unit on a hot surface or beside a heat
absorbing device.
- The air intake temperature must be under 40°C
- The operating staff has to make sure that installation,
support and inspection is done by qualified personnel.
3.3
Aufstellung Tischmodelle AKI0, AKI1, AWI1
Several units can be screwed
flush together by means of screws
1 and 2.
2.2
Technical Data
Max. tolerance of
the nominal supply
voltage
Nominal tension:
+6% / -10%
Supply frequency
50 / 60 Hz
Protection class
IPX2
Minimal diameter
of the pan
12 cm
Type
Description
Electrical connection
Power
Fuse
Cable
Weight
AKI0
1 Zone Table top
230V AC 1NPE 50/60Hz
3.5 kW
16A
H07RN-F 3G1.5
19.3 kg
BKI0
1 Zone Built in
230V AC 1NPE 50/60Hz
3.5 kW
16A
H07RN-F 3G1.5
15.8 kg
AWI1
Wok Table top
230V AC 1NPE 50/60Hz
3.5 kW
16A
H07RN-F 3G1.5
20.1 kg
BWI1
Wok Built in
230V AC 1NPE 50/60Hz
3.5 kW
16A
H07RN-F 3G1.5
16.6 kg
AKI1
2 Zones Table top
400V AC 3PE
50/60Hz
7.0 kW
16A
H07RN-F 4G2.5
25.5 kg
BKI1
2 Zones Built in
400V AC 3PE
50/60Hz
7.0 kW
16A
H07RN-F 4G2.5
22.0 kg
AKI0
1 Zone Table top
400V AC 3PE
50/60Hz
5.0 kW
10A
H07RN-F 4G1.5
20.3 kg
BKI0
1 Zone Built in
400V AC 3PE
50/60Hz
5.0 kW
10A
H07RN-F 4G1.5
16.8 kg
AWI1
Wok Table top
400V AC 3PE
50/60Hz
5.0 kW
10A
H07RN-F 4G1.5
21.1 kg
BWI1
Wok Built in
400V AC 3PE
50/60Hz
5.0 kW
10A
H07RN-F 4G1.5
17.6 kg
AKI1
2 Zones Table top
400V AC 3PE
50/60Hz
10.0 kW
16A
H07RN-F 4G2.5
27.0 kg
BKI1
2 Zones Built in
400V AC 3PE
50/60Hz
10.0 kW
16A
H07RN-F 4G2.5
23.5 kg
Storage
Function
> -20°C to +70°C
> + 5°C to +40°C
Storage
Function
> 10% to 90%
> 30% to 90%
Max. ambient temperature
Max. relative humidity of air
Min. wall clearance 4,0 cm
615
22
20
0-
21
0
38
0
When installing in a niche, consider to
carry away the outgoing air by means of slots
upwards, or lateraly under the cover.
Under no circumstances operate the unit
without sufficient air discharge!
1
2