VERTICAL PUMP
RDV - RGV - RCV
RBV - RNV - REV
EN-28
6.3.
PIPES
6.3.1. MAXIMUM PERMISSIBLE LOADS
The forces and moments acting on the pump flanges due to pipeline loads can cause an excessive stress on the fixing
bolts and/or break of the discharge pipe.
The maximum admissible load values on the flanges are shown in Table 6.
z
y
x
DISCHARGE PIPE
(S 235 JR - STEEL)
DN
Fy
Fz
Fx
Ftot
My
Mz
Mx
Mtot
32
327
404
347
625
289
327
424
608
40
385
481
424
748
347
404
501
731
50
520
635
578
1004
385
443
539
797
65
655
809
712
1261
424
462
578
852
80
789
963
866
1516
443
501
616
909
100
1040
1290
1155
2019
481
558
674
999
125
1232
1521
1367
2387
578
732
809
1234
150
1559
1925
1733
3023
674
789
963
1415
200
2079
2580
1925
4023
886
1020
1251
1848
Table 6 - Values of the maximum permissible loads