10.3. Electric connection for the oven to the mains
Electric connection of the oven to the mains must be carried
out by a professional electrician. The cost of the same must be
pay by the client.
If the oven is prepared to work at
230 V. III
, through the lar-
ge gland on the back of the base, insert a hose with three
conductors
“R”
,
“S”
and
“T”
, plus earth, with the appropriate
section according to the total consumption of the oven, con-
nected respectively to the “
R”
,
“S”
,
“T”
and earth terminals
installed in the bottom module.
If the oven is prepared to work at
400 V. III
, as well as the hose
and earth, as indicated in the previous paragraph, you must
also insert the
“neutral”
conductor through one of the plastic
glands on the back of the base and connect it to the terminal
strip on the bottom module marked
“N”
(See diagram).