The tables below outline power, electricity consumption and cable sections for both
230 V
and
400 V
. Using the information contained in the tables it is possible to cal-
culate cable sections in line with the
EN 60204-1
regulation.
MODEL
20
Module
30
Module
PIZZA
Module
Steam
generator
Proofer
POWER
(kW)
E
7.8
9.8
9.8
1.4
2.2
ED
13
16.3
--
2.5
--
EM
4.9
--
6.2
1.4
1.1
EMD
9.1
--
11.5
2.5
2.2
NXE
9.4
12.3
12.3
1.4
2.2
NXD
17.3
--
--
2.5
--
NXM
6.6
8.2
8.2
1.4
1.1
LXP
11.4
--
--
1.4
--
CON-
SUM.
(A)
230/400V
E
21.6/12.4
27.0/15.6
27.0/15.6
3.5/2.0
10/--
ED
34.7/19.3
43.5/24.1
--
6.3/3.6
--
EM
13.6/7.8
--
17.0/9.8
3.5/2.0
5/--
EMD
25.1/14.5
--
31.7/18.3
6.3/3.6
10/--
NXE
25.9/14.9
34.1/18.6
34.1/18.6
3.5/2.0
10/--
NXD
45.9/26.4
--
--
6.3/3.6
--
NXM
18.3/10.5
22.8/12.4
22.8/13.1
3.5/2.0
5/--
LXP
30.2/16.9
--
--
3.5/2
--
The supply cable sections required by the
EN 60204-1
regulation are calculated
using the total electricity consumption of the installed oven
For example, the total consumption of an
“E”
oven formed by
2
decks of
20 cm
1
deck of
30 cm
height with steam gen
1 “Pizza”
deck +
1 Proo-
fer
, connected at
400 V.
“E”
OVEN
Quantity
Consumption
/ unit
Part
consumption
20 cm Module
2
12.4
24.8
30 cm Module
1
15.6
15.6
PIZZA Module
1
15.6
15.6
Steam generator
1
2.0
2.0
Proofer
1
10
10
Total consumption
68 A
Содержание modular 2013
Страница 31: ...Previas_Modular_13_ c f i 300413 31 salva E S P A O L...
Страница 60: ...60 Previas_Modular_13_ c f i 300413 salva F R A N A I S...
Страница 89: ...Previas_Modular_13_ c f i 300413 89 salva E N G L I S H...
Страница 90: ...90 Previas_Modular_13_ c f i 300413 salva E N G L I S H...
Страница 91: ...Previas_Modular_13_ c f i 300413 91 salva E N G L I S H...