![Salutron HardyTest HARTIP 1800 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/salutron/hardytest-hartip-1800/hardytest-hartip-1800_operation-manual_3628958017.webp)
15
6.6.1.
Memory on/off
Choose
Memory on/off
from memory menu and press
►
button to enter sub-menu.
Press
▼
or
▲
button to choose the option to be set and press
►
button to confirm the
option.
Figure 6-19 Memory on/off Menu
Off
: If this option is chosen, the instrument will not store measured values. After the
operation is successful, “Successfully” is showed on the screen of instrument. The screen
will return to the Memory menu in 1 sec. The default value is Off.
Current block
: If this option is chosen, the instrument will store the measured value into
the current block. After the operation is successful, “Successfully” is showed on the
screen of instrument. The screen will return to the Memory menu in 1 sec. The current
block is storage block that is set by the user at the last time. If capacity of this storage
block is full, a new block will be created automatically after this block. The default
memory block is 001.
After Current block is set, current block No. and the measured value No. of this block will
be showed on the top of measuring mode, e.g. “B001 001”, indicating the first block and
the first measured value.
Select block
: Press
►
button to enter Select block window. On this window, the current
block can be set as any block of existing blocks. Press
▼
button to move the cursor and
choose the value of modified group No., cycling from hundreds, tens, units to return in
turn. When the cursor is moved to the option of “
Back
”, by pressing
►
button, the
instrument returns the memory menu. Press
▲
button to modify the value at the chosen
digit (0-9 cycle). After setup is finished, press
►
button to confirm the setup. After the
operation is successful, “Successfully” is showed on the screen of instrument. The screen
will return to the Memory menu in 1 sec. If group No. user chosen is beyond total group
No., “Block not exist” will be showed on the screen of the instrument. The screen will
return to the Select block Window in 1 sec.
Figure 6-20 Select block Window
New block
: If this option is chosen, one new block will be created as current block. After
the operation is successful, “Successfully” is showed on the screen of instrument. The
screen will return to the Memory menu in 1 sec. Total 400 blocks can be created in the
instrument. 999 data can be stored in each block. When storage capacity of all blocks is
full, “Out of storage” will be showed on the screen of instrument. At this time, the users
can empty the memory or delete the memory blocks to release the storage space. Users
can view the storage status through System info.
If the users do not make any modification, they can press
▼
and
▲
button simultaneously
to return the Memory menu.
Содержание HardyTest HARTIP 1800
Страница 1: ...HARDNESS TESTER HardyTest HARTIP 1800 OPERATION MANUAL...
Страница 2: ......
Страница 11: ...9 6 2 Diagram of Operation Figure 6 2 Diagram of Operation...
Страница 38: ...36 11 4 Quit the program After finish all the job you can click from the tool bar to quit the program...
Страница 39: ......