Weather  controller  WT100  is  designed  to 
control the temperature in the heating circuit 
with  the  valve  3  or  4-way  equipped  with  a 
drive-controlled 3-point with the possibility of 
connecting  additional  circulation  pump  and 
control the heat source through a dry contact.  
Main functions performed: 

 

weather control - the preset temperature 
heating circuit is determined on the basis 
of the programmed heating curve and the 
measured outside temperature, 

 

automatic detection season heating, 

 

work with a room thermostat 

 

controling the heat source 

 

implementation of the return temperature 
protection (against low temperature of the 
return  water)  -  protection  from  boiling 
water  in  the  boiler  (coal  boiler)  in  the 
short-circuit of the boiler. 

The controller is equipped with a timer (clock 
operation is maintained for 48 hours with the 
power off the controller).  
Regulator  is  easy  to  operate  in  an  intuitive 
manner.  It  may  be  used  in  households  and 
other  similar  premises  and  in  light  industry 
facilities. 

 

Information about documentation 

The  regulator  manual  is  divided  into  two 
parts:  for  user  and  fitter.  Yet,  both  parts 
contain important information, significant for 
safety issues, hence the user should read both 
parts of the manual. 
We  are  not  responsible  for  any  damages 
caused  by  failure  to  observe  these 
instructions. 

 

Documentation storage 

Please  keep  this  operation  and  assembly 
manual  and  other  valid  documentation  in  a 
safe  place  for  future  reference.  In  case  of 
moving  or  selling  the  device,  hand  this 
documentation over to a new user or owner. 

 

Used symbols 

The  following  graphical  symbols  are  used  in 
the manual: 

     - useful information and tips, 

  -  useful  information  concerning 

property  damage,  health  or  life  threat  for 
people or pets. 
 
Caution:  important  information  were  labeled 
with  the  aforementioned  symbols  in  order 
make  the  manual  easier  to  understand. 
However  it  does  not  release  the  user  nor 
installer from responsibility of complying with 
requirements which are not labeled with any 
symbols! 

 

WEEE Directive 2012/19/UE 

Purchased  product  is  designed  and  made  of 
materials of highest quality. 
The  product  meets  the  requirements  of  the 
Directive 2012/19/EU of 4 July 2012 on 
waste 

electrical 

and 

electronic 

equipment (WEEE), according to which it is 
marked by the symbol of crossed-out wheeled 
bin  (like  below),  meaning  that  product  is 
subjected to separate collection. 

 

Responsibilities  after  finishing  a  period  of 
using product: 

 

dispose  of  the  packaging  and  product  at 
the  end  of  their  period  of  use  in  an 
appropriate recycling facility,  

 

do  not  dispose  of  the  product  with  other 
unsorted waste,  

 

do not burn the product. 

By adhering obligations of waste electrical and 
electronic  equipment  controlled  disposal 
mentioned  above,  you  avoid  harmful  effects 
on the environment and human health.  
 
 
 
 
 
 
 

Содержание WT100

Страница 1: ...WEATHER CONTROLLER WT100 FOR CONTROL TEMPERATURE HEATING CIRCUIT OPERATIONS AND INSTALLATION MANUAL VERSION 1 4 SOFTWARE VERSION v01 XX XX 03 2018...

Страница 2: ...2...

Страница 3: ...THE CONTROLLER 15 ENVIRONMENTAL CONDITIONS 15 INSTALLATION REQUIREMENTS 15 EXTERNAL CIRCUITS CONNECTION 16 CONNECTING ELECTRICAL SYSTEM 17 FIXING THE EXTERNAL WIRES 17 CONNECTION OF TEMPERATURE SENSO...

Страница 4: ...t in case of failure it can be a source of sparks or high temperature which surrounded by ashes or flammable gases can cause fire or explosion Modification of the programmed parameters should be made...

Страница 5: ...to observe these instructions Documentation storage Please keep this operation and assembly manual and other valid documentation in a safe place for future reference In case of moving or selling the d...

Страница 6: ......

Страница 7: ...REGULATOR INSTRUCTION MANUAL WT100...

Страница 8: ...ixer actuator position ON open OFF closed STOP off 5 working heat source boiler switched on 6 information from the room thermostat No icon the thermostat is off Heating room temperature below the pres...

Страница 9: ...mperature In periods of night heating circuit is completely turns off The frost protection function remains active as long as it is enabled in the Service menu Schedule The time intervals allow the in...

Страница 10: ...turned on automatically using the Auto parameter including temperature settings for the Summer mode ON temp and Summer mode OFF temp General settings In general settings can change the settings date t...

Страница 11: ...INSTALLATION MANUAL AND SERVICE SETTINGS WT100...

Страница 12: ...vice settings Room thermostat Start pump temp 55 C 20 C Service settings Heating circuit Return sensor ON Service settings Protection In order to improve water flow in gravitational circuit of the boi...

Страница 13: ...source with S ON OFF contact gas or oil boiler 2 relief valve different pressure 3 hydraulic coupling RECOMMENDED SETTINGS Parameter Setting MENU Kind of the system Radiators system Service settings...

Страница 14: ...y valve actuator 1 heat source with S ON OFF contact gas or oil boiler 2 relief valve different pressure 3 hydraulic coupling RECOMMENDED SETTINGS Parameter Setting MENU Kind of the system Underfloor...

Страница 15: ...unit casing disconnect power supply The unit installation must be done at disconnected voltage Controller must be installed by qualified and authorized technician in accordance with EN 60335 1 standa...

Страница 16: ...50Hz P CH pump SM mixer actuator S contact to operate the heating source type ON OFF FU time delay subminiature fuse The terminals for hazardous voltage COM NO ZLo ZN ZLc PN PL L N The terminals safe...

Страница 17: ...supply 230V to terminals for sensors will damage the regulator and creates risk of an electric shock Tips of the connected wires especially power leads must be secured against splitting by means of in...

Страница 18: ...e may be shown Minimum length between those wires should be 100mm It is not acceptable to allow for contact betweens wires of the sensors and hot parts of the boiler and heating installation Wires of...

Страница 19: ...pump in the parameter Off by thermostat The values of the parameters must be chosen so that when of working the room thermostat contact opening the temperature in the room dropped Connecting a heat so...

Страница 20: ...ease of work mode 0 15K 10 Decrease of thermostat 0 30K 10 OFF by thermostat Yes No Yes Start pump temp 10 70 C 35 Min temperature 5 40 C 20 Max temperature 20 50 C 40 Valve full opening time 60 200s...

Страница 21: ...ning the thermostat Preset temperature of water inside the heating circuit is not changed if Decrease of thermostat 0 Parameter disappears when Room thermostat OFF OFF by thermostat Stopping the flow...

Страница 22: ...an accuracy of 1 Frost protection ON or OFF frost protection function Frost protection delay Time delay for enable frost protection function Description later in this manual Frost protection temp The...

Страница 23: ...move In this setup it is possible to connect a room thermostat which will equalize the inaccuracy of selecting heating curve if the selected heating curve value is too high In such case it is necessa...

Страница 24: ...vices settings Protection Frost protection Description of frost protection against the external temperature sensor readings When the external temperature drops below 3 C an Frost protection delay e g...

Страница 25: ...5 C Technical data Power 230V 50Hz Maximum current consumption with loaded outputs 3 3 A Maximum current consumption without loaded outputs 0 02A Output current Pump Mixer actuator ON Mixer actuator O...

Страница 26: ......

Страница 27: ......

Страница 28: ...SALUS Controls ul Rolna 4 43 262 Kobielice Poland www salus controls pl...

Отзывы: