22
HW priority
ON
– When the temperature of the heat source is lower than the
Min. temperature
for
the circuit, the controller lowers the circuit preset temperature, but only when there is
no active reduction from the operation mode.
OFF
– the regulator does not reduce the circuit preset temperature.
Cooling temp.
Temperature value at which heat excess is discharged to the heating circuit. It is protection
against overheating.
OFF by thermostat
Turns off heat source when the starting thermostat contact.
Increrase temp.
Increase of the heat source preset temperature above the heating circuit preset temperature.
Protection
Return sensor
Turns on
or
off
support of the return temperature sensor. Enabling the sensor support shows
additional parameters related with the function of protecting the boiler return from cold water.
It is realized through a mixing valve with an electric actuator. Note: Do not turn sensor support
if there is no electric actuator mounted on the valve! This function is not available when the
return sensor is not connected or its support is disabled. Function activation results in valve
closing.
Min. temperature
The temperature below which the electric actuator turn a blind mixing valve.
Histeresis
Electric actuator will return to normal working at return temperature
≥
Min. temperature
+
Hysteresis
.
Closing the valve
It is % opening to the mixing valve during active the return protection function. Note: The
valve closes with an accuracy of +-1%.
Frost protection
ON
or
OFF
frost protection function.
Frost protection delay
Time delay for enable frost protection function. Description later in this manual.
Frost protection temp.
The temperature below which the frost protection function is activated . Description later in
this manual.
Other parameters
Room thermostat
ON
or
OFF
supporting the room thermostat (NO-NC).
Temperature correction
Additional correction of the errors for the temperature sensor: T1 - heating circuit, T2
–
external, T3
– return, T4 - boiler.
External sensor
Enable support external temperature sensor (weather) for controlling the heating circuit. In
the event of external sensor damage on the screen displays the message " Damage sensor
external temperature ". Enabling support cause additional parameters in the menu to the
weather control.
Manual control
Manually turn
ON
or
OFF
working CH pump, mixer actuator, contact the heat source in order
to control the correctness of their actions.
Note: The long time activation of the pump - can be damaged this pump.
Screed drying
Activating
or
Deactivating
the screed floor drying function (heating by floor circuit). Schedule
of temperature changes in time is shown on the screen in the form of graphs appropriate for
programs P1..P7. Select the correct program for the used type of screed and environmental
conditions.
Drying is performed by a corresponding change in floor circuit temperature in the range
10..50ºC in a time of 30 days.
Drying can be deactivating at any time. Re-activation function
makes that the drying works all over again for 30 days.
Restore defaults settings
Selecting
YES
will reload all the factory settings.