background image

Introduction

The EP210 dual channel programmable controller is a stylish wired timer that can be used for central heating 
and also for the hot water. Each output will control one zone, meaning that you can create personalized 
schedules for each channel. 

The EP210 programmable controller will switch ON and OFF your central heating system and/or hot water in 
your home as needed. It works by controlling the heating boiler according to a series of programmed settings 
that take effect at different times of the day. 

By using the EP210 controller you can manage the commands sent to your boiler, motorized valves used in 
your system or to your thermostat. You can set the EP210 programmable controller to a 12 or 24 hour format, 
the Daylight saving Time (DST) being automatically enabled. The program mode is also selectable between a 
5-2 (Monday-Friday and Saturday-Sunday) or 24 hour format. For each of the programs you can create three 
settings per day.

Being a complex programmable controller, the EP210 gives you the possibility to override your programs by 
using the Boost function. This can be enabled for up to 9 hours.

For the periods when you are away you can use the Holiday function, which will turn off the relay. The Holiday 
Mode can be set for a period of maximum 31 days.

When connected to a system with a non-programmable (digital) thermostat, it can turn the boiler ON or OFF 
and control the heating and/or hot water in your system in a programmed manner. 

The heating system and the hot water will be controlled with the EP210, meaning that this will send the 
command of turning the relay on or off when needed, according to the programs created.  

The EP210 programmable controller does not detect or adjust the temperature in your house, it is just sending 
the commands to the boiler, motorized valve or the thermostat to turn ON or OFF the relay, depending on the 
program settings. 

The programs can be set individually for each channel, or, you can program them together if you want your 
heating and hot water to be controlled in a coordinated manner.

EP210 Installation Manual      03

Содержание EP210

Страница 1: ...Installation Manual Model EP210 Dual channel programmable controller ...

Страница 2: ...duct Compliance 4 Safety Information 4 Box content 4 Features 5 Installation 5 Button functions 7 LCD icons 8 Operations 9 Functions 18 Factory Reset 21 Technical Info 22 Warranty 23 Contents 02 EP210 Installation Manual ...

Страница 3: ...gs per day Being a complex programmable controller the EP210 gives you the possibility to override your programs by using the Boost function This can be enabled for up to 9 hours For the periods when you are away you can use the Holiday function which will turn off the relay The Holiday Mode can be set for a period of maximum 31 days When connected to a system with a non programmable digital therm...

Страница 4: ...EU and 2011 65 EU Please check www saluslegal com for the full information Safety Information Use in accordance with the EU and national regulations For indoor use only Installation Jumper Settings First Power Up Model EP110 EP210 EP310 Input 230V 50Hz Output 3A switch terminal 1 2 EP110 Volt Free application only EP210 230V Application EP110 230V Application Only Note Please remove red link wire ...

Страница 5: ...entral Heating On Earth Parking no electrical connection N L 1 2 3 4 N L 1 2 3 4 Features Dual Channel Programmer for Central Heater or Hot Water 12 or 24 hour clock format 5 2 or 24 h individual programs with 3 settings per day Boost function Holiday function Advance function Memory backup N L 1 2 3 4 N L HW CH HW CH off off on on EP210 Installation Manual 05 ...

Страница 6: ...ry disabled Note Changes to the jumper setting should only be made by the engineer carrying out the installation or another qualified person The installer should select the jumper positions required if changes need to be made to the factory default settings These jumpers are found on the rear of the controller The jumpers are found on the rear of your controller and can be used to change the setti...

Страница 7: ... setting of clock date week day etc Set Press to confirm the setting Up arrow Press to increase clock day press and hold to enter fast advance Down arrow Press to decrease clock day press and hold to enter fast advance Press to activate backlight Hardware reset Press and hold button for 3 seconds to activate Holiday mode Select Set Press and hold buttons to enter clock setting mode MODE MODE Hr Hr...

Страница 8: ...heating Holiday Mode Boost hours for hot water AM PM 1 2 3 4 5 6 7 Days of the week 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 OFF Mode ADV Mode On AUTO Mode On ONCE Mode On On Mode DST On Off 8 9 10 11 12 13 14 Hot Water On 15 Program number 08 EP210 Installation Manual ...

Страница 9: ... version is shown and after that the typical reset display is shown The time should be 12 00am Default settings MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET Function Status after Reset Operation Mode Normal mode Clock 12 00 AM AM PM indicator AM Date January 1 2016 Daylight Saving Time DST On Program Factory default 5 2 Program Number indicator Off SET indicator...

Страница 10: ...r controller First you will need to set up the time and then the date To enter clock setting mode press and hold Select and Set buttons for 3 seconds Please follow the instructions below Press Select to confirm MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET Press Select to confirm MODE MODE Hr Hr SELECT SET Press Select to confirm MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET MODE M...

Страница 11: ...On for 1 period a day from Program 1 ON to Program 3 OFF AUTO Automatic program control ADV When device is in Auto or Once mode press the MODE button for 3 sec for selecting Advance ADV This will move the unit into the next program When the ADV function ends the device will return to normal program OFF Continuously off Operating Modes For activating the functions described above press the MODE but...

Страница 12: ...n ONCE mode the controller gives the boiler the command to run only for one period per day from program 1 ON to program 3 OFF MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET Press for CH mode Press for HW mode MODE MODE Hr Hr SELECT SET Press for CH mode Press for HW mode ONCE Mode Auto Mode Press for CH mode Press for HW mode Pressing the Mode key 3 times activates the AUTO In AUTO mode the...

Страница 13: ...tput to ON from 10 00 onwards back to AUTO which is also ON If the ADV puts the relay ON then the boost would apply immediately at the next OFF change if the ADV put the relay OFF then the boost would apply immediately and turn the relay ON 08 00 OFF 10 00 ON 12 00 OFF 14 00 ON If ADV occurs at 08 30 and the relay is ON from 08 30 to 12 00 During this period if at 08 45 1Hr Boost is pressed the re...

Страница 14: ...ou can program the schedules for these outputs individually or together When you program them together there will be the same program time for both Heating and Hot Water If you choose to program them individually you can have different program times for each 5 2 Program MODE MODE Hr Hr SELECT SET Press Set to enter setting programs MODE MODE Hr Hr SELECT SET The CH icon and Mon Fr will start flash...

Страница 15: ...HW individually goes at it follows Weekday CH program 1 3 Weekday HW program 1 3 Weekend CH program 1 3 Weekend HW program 1 3 and all over again Note To save your settings and exist to home screen in normal mode press Set at any time Programming CH and HW together The programming principle is exactly the same but you can only set the same Start End time for the CH and HW The programming sequence ...

Страница 16: ...r SELECT SET The CH icon will go steady the program number will appear and you will need to select a start time for the CH program Use up down arrows Programming CH and HW individually 6 MODE MODE Hr Hr SELECT SET 6 Press Select MODE MODE Hr Hr SELECT SET Use up down arrows to select minutes 6 MODE MODE Hr Hr SELECT SET 6 Press Select 6 MODE MODE Hr Hr SELECT SET 8 Press Select MODE MODE Hr Hr SEL...

Страница 17: ...esday HW program 1 3 Wednesday CH program 1 3 Wednesday HW program 1 3 etc Note To save your settings and exist to home screen in normal mode press Set at any time Programming CH and HW together MODE MODE Hr Hr SELECT SET Press Set to enter setting programs MODE MODE Hr Hr SELECT SET The CH icon and Mon will start flashing Press up arrow 2 times MODE MODE Hr Hr SELECT SET Press Select to start ent...

Страница 18: ...f the number rolls back to blank this will disable the Boost Override Press 1Hr to enter Boost override The number of boost hours will be displayed To exit boost override press mode button until number x disappears MODE MODE Hr Hr SELECT SET Boost Override 1Hr override for Heating MODE MODE Hr Hr SELECT SET 1 MODE MODE Hr Hr SELECT SET Press 1Hr to enter Boost override The number of boost hours wi...

Страница 19: ...r override Boost is running then ADV is selected ADV will be activated and the previous 1Hr override will be canceled Long press Mode while in Auto or Once to enter ADV override Mode Short press Mode while in ADV to exit mode back to auto or Once ADV Override for Heating ADV Override for Hot Water MODE MODE Hr Hr SELECT SET Long press Mode while in Auto or Once to enter ADV override Mode Short pre...

Страница 20: ... be to set the number of holiday days up to 31 To exit Holiday Override and turn On the relay long press the key Press Up Down keys to select days Enter Holiday Mode Exit Holiday Mode Press for 3 seconds Press for 3 seconds Controller in current mode LCD Backlight If AC is powered LCD backlight is activated when or any key is pressed The backlight will be turned off in 15 seconds after all keys ar...

Страница 21: ...n once use a pin for this action Press reset button LCD will turn OFF All icons will be displayed Software version MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET Normal Mode MODE MODE Hr Hr SELECT SET EP210 Installation Manual 21 ...

Страница 22: ...0 non condensing Storage Temperature Humidity 20 C 60 C 10 90 non condensing Programs Program 5 2 or 24hr individual program selectable by jumper 3 settings day with holiday override Boost Override Yes max 9 hours selectable by software Holiday Override Yes max 31 days selectable by software Clock Clock Format 12 or 24 hour selectable by software Clock Accuracy 1 min month Daylight Saving Time DST...

Страница 23: ...ecification for a period of two years from the date of installation SALUS Controls sole liability for breach of this warranty will be at its option to repair or replace the defective product Customer Name Customer Address Post Code Tel No Email Company Name Tel No Email Installation Date Installer Name Installer Signature EP210 Installation Manual 23 ...

Страница 24: ... tech salus tech com www salus controls com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserves the right to change specification design and materials of products listed in this brochure without prior notice For the latest PFD Instruction Manual go to www salus manuals com Issue Date April 2017 V001 ...

Отзывы: