Tel: 886.909 602 109 Email: [email protected]
22
Note
: When accessing to the
Menu
item, you can press
or
Exit
to exit the menu operation.
No matter which function the instrument is performing, you can exit the function operation status
by pressing the key
. .
4.6.2 Menu Function
The output state setup after the instrument powered on (>Out Memory)
This instruction is used to set the output state when the power supply is powered on. If you select the item
On
,
the power supply will set the output to OFF state when the power supply is powered on. If you select the item
Off
, the output will remain the same state as last time you turned off the power supply.
Setting the Key Sound (Key Sound)
This instruction can switch on/off the buzzing sound when you press any key, If you select the item
On
, the
buzzer will sound when any key was pressed. If you select
Off
, the buzzer will not sound when the keys were
pressed. Default setting is the item
On
; the buzzer will sound when you press any key.
Setting the Baudrate (>Baudrate Set)
This instruction can change the communication baud rate of the power supply; the baud rate range is 4800bps,
9600bps, 19200bps, 38400bps. Before the communication, you must make sure that there is same baud rate
between the power supply and the computer. Default baud rate is 9600bps.
Setting Password for Function Keys (>Key Lock Set)
This instruction can set a password (1 through 8 digits) to lock the function keys operation. After setting the
password, the key
V-Set,Save,Recall,Menu
will be locked if no operation on keyboard in 60 seconds. Only if
you put the correct password, the above keys are able to unlock. If you don’t want to lock the function keys,
please don’t press any number key or just put
0
when you enter the
Key Lock Set
item, just press
key to unlock it.
List Operation (>List Set)
You can set every single-step value and duration time by new list operation so as to get different output list.
The parameters of the list operation include the name of the list file which are input, input single step numbers
(200steps at most), single step duration time (1mS at least) and the setting value of every single step.
When list operation is under
Continuous
mode, the power supply will begin the list operation until the list
operation is finished or until receiving the next trigger signal.
Before editing the list, if you want to change the file storage format, please operate as the following steps:
1) Press the keys
and
to access to the menu function.