4.4 Constant Current Operation
The constant current output range is from 0 A to the maximum current value of each type. It is very easy for
you to set the constant current output.
Step1. Power on the SPS8 series instrument
Step2. Press
key
Step3. Use the numeric keys
to
to enter the voltage value you wanted
Step4. Press
key to confirm the value
If you close knob lock function in config menu, please use following operation:
Press
key then use upper revolving encoder to adjust voltage
4.5 Saving and Recalling Operation
You can store up to 50 different output states in storage register locations(0~49) so that you can recall the saved
settings quickly. This kind of store operation can be performed by the keys
and
located in
the front panel. When the fast recalling is activated, you can press the numberic keys
to
to invoke
the corresponding data.
Each output state includes: 1. Constant voltage value, 2. Constant current value, 3. Maximun voltage setting
value, 4. Step voltage value.
After you setting an output state (CV value, CC value and Maximum voltage), press the
key
and the numeric keys
to
to store the output value in a specified memory location.
Press the
key and the numeric keys
to
to recall the output value from a specified memory
location.
4.6 Menu Operation
4.6.1 Menu Description
Press the key
to access to the menu function and at the moment the VFD display screen shows the
menu items. You can select the menu items by pressing the ▲ and ▼ keys or by rotating the knob, and then
press the key
to enter in the menu item you wanted. Or you can press the key
to get back to
the higher level menu.
The first level menu includes:
V-Set
Enter
0
Enter
I-Set
0
Save
Recall
0
0
V-Set
I-Set
0