background image

15

Содержание C3235

Страница 1: ...ront panel of the unit The front panel includes the display window the annunciators arrayed around the display the four keys and the bubble level Figure 1 1 C3235 front panel NOTE This product is rate...

Страница 2: ...ust recharge the battery soon CAEnd This is displayed when calibration is finished Err 0 A zero point error has occurred C_End This is displayed when the battery is fully recharged ZERO key Press this...

Страница 3: ...e inactivity the scale goes into auto power saving mode and the display shows a small o To wake the scale up place a weight on the scale platform 4 If the battery voltage drops below 5 6V the scale wi...

Страница 4: ...emove the item s and repeat steps 2 through 4 for the next item s 4 0 Tare weighing 1 Power up the scale 2 Zero the scale if necessary by pressing the ZERO key 0 is displayed 3 Place the item to be ta...

Страница 5: ...weight is displayed and the Over Accept or Under annunciator lights You must set the acceptable window parameters in the Configuration menu which is described in rAnGE on page 6 4 Remove item from the...

Страница 6: ...h of these parameters is described below Accessing the Configuration Menu and Setting Parameters To access the Configuration menu press and hold the F key for three seconds rAnGE the first menu item i...

Страница 7: ...eighed Remember as you set the values for the lower and upper ranges that the decimal does not appear on the display but you enter the values as if it were For example If you want 2 85 pounds as the h...

Страница 8: ...through the choices Lb Lb This is the pounds unit of measure Lb oZ This is the pounds ounce unit of measure PcS This is the counting function HG This stands for KG or kilogram G This is the gram unit...

Страница 9: ...o enter 25 you must press the TARE key three times to move the flashing digit to the right three times then enter 2 and 5 so the display looks like this 00025 After the last digit is entered the scale...

Страница 10: ...s displayed This is the filter setting The noisier the environment the scale is in the higher the filter setting you should choose This means if the scale sits in a place that is subjected to vibratio...

Страница 11: ...he choices When your choice is displayed press the TARE key 5 The function is set and the scale returns to normal weighing mode 7 0 Calibration You can calibrate this scale using single point or multp...

Страница 12: ...hold the TARE key to enter calibration and repeat the calibration process Multipoint Calibration Follow these steps for multipoint calibration of the scale You will need test weights equal to 1 3 2 3...

Страница 13: ...ter and press the TARE key when the display becomes stable The display shows c 0 with the c flashing At this point you can input a gravity adjustment 10 Press ZERO to increment the factor by one Press...

Страница 14: ...15 30 Max Cap 3kg 6lb 6kg 12 lb 15kg 30lb Division Size 0 5g 0 01 lb 1g 0 02 lb 2g 0 05 lb Max Tare 100 Accuracy Class III Pan size 7 5 x 9 Working Temperature 23 95 F 5 35 C Power 6V4 5Ah rechargeab...

Страница 15: ...15...

Страница 16: ...ll Weighing Products 1000 Armstrong Dr Fairmont MN 56031 Toll free 800 637 0529 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com www salterbrecknell com October 2014 C3235_u fm AWT35...

Отзывы: