6
You use the Configuration menu to set the following parameters:
rAngE
Use this to set the Over/Accept/Under ranges.
Units
Use this to set the unit of measure and to enter the count
mode.
A-OFF
Use this to enable or disable the auto-off function. If enabled
the scale will power off automatically after 10 minutes of
inactivity.
FILt
Use this to set the level of filtering.
Zero
Use this to set the automatic zero tracking window.
bUZZEr
Use this to enable or disable the beeper.
How to set each of these parameters is described below.
Accessing the Configuration Menu and Setting
Parameters
To access the Configuration menu, press and hold the
F
key for three
seconds…
rAnGE
, the first menu item, is displayed.
rAnGE
Use this item to set the weight ranges which will trigger the Over/Accept/
Under annunciators.
1.
Press and hold the
F
key for three seconds to access the
Configuration menu …
rAnGE
is displayed.
2.
Press the
TARE
key…
on
or
oFF
is displayed.
3.
Press the
F
key to toggle between the choices. To enable the range,
press the
TARE
key with
on
displayed. (Go to step
range function, press the
TARE
key with
oFF
displayed. (Go to step
)
4.
If you enabled the range function…
Содержание C3235