background image

APD-100 Automatic Powder Dispenser User Instructions

11

1.9    FCC and EMC declarations of compliance

1.9 FCC and EMC declarations of compliance

United States

Canada

European Countries

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a 
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own 
expense.

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio 
Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de 
la Classe A prescrites dans le Règlement sur le brouillage radioélectrique edicté par le ministère des Communications du Canada.

WARNING:

 This is a Class A product. In a domestic environment, this product may cause radio interference in which the user may be 

required to take adequate measures.

Содержание APD-100

Страница 1: ...APD 100 Automatic Powder Dispenser User Instructions AWT35 500571 IssueAB March 2011...

Страница 2: ...der license Full acknowledgment of the source must be given Avery Weigh Tronix is a registered trade mark of the Avery Weigh Tronix LLC This publication was correct at the time of going to print howev...

Страница 3: ...mponent Identification 13 Chapter 3 Installation 15 Powering On and Powering Off the APD 100 16 Chapter 4 Operating the APD 100 17 Calibration 17 Powder Type Selection 18 Weighing and Dispensing 18 Au...

Страница 4: ...4 APD 100 Automatic Powder Dispenser User Instructions...

Страница 5: ...sages appear in bold italic type and reflect the case of the displayed message 1 1 2 Special messages Examples of special messages you will see in this manual are defined below The signal words have s...

Страница 6: ...uipment Avoid areas where static electricity is evident Do not use primers of unknown identity Discard unknown primers in accordance with applicable regulations Keep primers in the original factory co...

Страница 7: ...om the scale before new powder is added Be sure to carefully remove powder feed tube and powder box and clear all powder residue Be sure the scale reads zero before dispensing powder If powder is disp...

Страница 8: ...ly stored If dropped or damaged have weights inspected against known standards l Static electricity can cause the scale display to drift If static buildup is evident wipe the scale with an antistatic...

Страница 9: ...FER TO QUALIFIED SERVICE PERSONNEL FOR SERVICE CAUTION The power adapter must be connected to an earth grounded electrical outlet The electrical supply must have a circuit breaker with an appropriate...

Страница 10: ...ally satisfactory to the user Take frequent breaks during prolonged usage 1 8 Sharp objects Do not use sharp objects such as screwdrivers or long fingernails to operate the keys Table 1 1 Cleaning DOs...

Страница 11: ...rference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his ow...

Страница 12: ...OFF AUTO REPEAT Press to enter to or exit from the AUTO REPEAT dispensing mode POWDER Press to select the type of POWDER ZERO EXIT Press to ZERO the scale or exit from input setting mode UNIT SETUP Pr...

Страница 13: ...uctions 13 2 2 Component Identification 2 2 Component Identification See the photos and the component list below to identify the parts of the system Figure 2 2 Front view Figure 2 3 Back view 2 5 1 19...

Страница 14: ...weighing pan 4 loadcell cover 16 powder feed tube 5 keypad 17 powder feed tube restrictor 6 powder reservoir base 18 J hook 7 powder reservoir tube 19 rubber key keypad 8 powder reservoir tube cover 2...

Страница 15: ...cover See Figure 3 1 Figure 3 1 Remove powder reservoir tube from storage area 4 Remove the powder reservoir cover and install the powder reservoir tube by pressing it into the powder reservoir base a...

Страница 16: ...ighing In the warm up mode the weighing powder dispenser and calibration features will be blocked however you can still enter settings into the memory as well as recall and edit existing memory 2 To t...

Страница 17: ...R to continue The A to D counts are displayed 4 Remove all weight from the weighing pan and press ENTER to perform the zero point calibration CAL 30 g is shown after zero calibration is complete 30 g...

Страница 18: ...the desired charge weight using the number keypad Press the EXIT key to exit the input mode press the BACKSPACE key to clear the last digit 5 When the desired charge weight is displayed press ENTER ke...

Страница 19: ...scale will drop another load 4 Press the STOP ZERO EXIT or the AUTO REPEAT key to exit the auto repeat function This will exit the auto repeat mode and the AUTO LED light will turn off 4 3 2 Manual Fa...

Страница 20: ...several seconds and the display will shift to the next space When the name is displayed press ENTER key Use the CANCEL or BACKSPACE key can to edit the input line POWD is briefly displayed then P _ 4...

Страница 21: ...y to recall a load in memory using the cartridge name C __ is displayed 2 Key in the name of the cartridge using the keypad and press the ENTER key to accept The cartridge name is displayed briefly an...

Страница 22: ...g mode 4 4 3 Edit Stored Information 1 Recall a memory to edit using one of the methods discussed in the previous sections 2 Press the EDIT key to edit the cartridge name powder or weight 3 Press the...

Страница 23: ...in memory 4 Press the FAST or TRICKEL v keys to move to another memory location or press the EXIT key to exit from memory and return to standard weighing and dispensing mode After the information in t...

Страница 24: ...ld the SETUP key until USER is displayed There are two menus containing parameters One is for the end user USER and the other is for configuration CONFIG of the unit 2 Press the FAST or TRICKEL v key...

Страница 25: ...zer to BZ OFF Press the 1 key to set the buzzer to BZ ON Press the ENTER key to accept the displayed choice The factory default setting is BZ ON USER is displayed This completes the items in the User...

Страница 26: ...e value displayed PUL XX is displayed This parameter sets the length of each pulse of the dispensing motor for delivering very small quantities of powder XX is the value of the setting Settings can be...

Страница 27: ...he 95 weight level to the 100 weight level Figure 5 3 Motor speed chart 8 Type in a value between 1 and 100 and press the ENTER key to accept the value displayed ERRX XX is displayed This is an error...

Страница 28: ...the weight is less than or equal to this value the APD 100 will automatically restart a new charge cycle If the weight is more than this value the display will show ERROR Values must be between 0 1 a...

Страница 29: ...D 100 place the rubber cap onto the end of powder feet tube and lower the powder cleaning chute on the rear panel behind the powder reservoir Be certain that you have a container under the chute to ca...

Страница 30: ...voir base 3 Insert the J shaped rod through the hole in the unit above the feed tube motor coupling Insert the rod through one of the small holes in the motor coupling See Figure 6 3 Figure 6 3 J shap...

Страница 31: ...ng powder that may still be in the tube Figure 6 4 Unscrewing and removing feed tube 5 Close the powder chute and then push the powder compartment in to release it from the unit The box will pop out s...

Страница 32: ...ERROR3 over capacity l ERROR4 input data error value is out of range 6 3 Packing List Below are the parts that should be packed with your APD 100 No PARTS QUANTITY 1 APD 100 scale 1 2 AC adapter 16Vd...

Страница 33: ...of capacity Zero Tracking Range 1 5d Working temperature 14 to 104 F 10 to 40 C Storage temperature 4 to 158 F 20 to 70 C 7 1 Weight Conversion Chart 7 1 1 Abbreviations Carat ct Grain gn Gram g Kilog...

Страница 34: ...D 100 Automatic Powder Dispenser User Instructions Specifications 7 1 2 Capacity and Division Size Accuracy 3d Capacity Division Accuracy Grams 100 0 005 0 015 Grains 1500 0 1 0 3 Ounces 3 5 0 0002 0...

Страница 35: ......

Страница 36: ...Salter Brecknell Weighing Products 1000 Armstrong Dr Fairmont MN 56031 Toll free 800 637 0529 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com www salterbrecknell com...

Отзывы: