background image

185HE SIMTAN 

So ener & Tannins 

Reduc on System 

Owners Manual 

REVISION # 0 
REVISION DATE 

9

/1

2

/201

9

 54832-1 

1. Read all instruc ons carefully before opera on.
2. Avoid pinched o

rings during installa on by applying (provided with install kit) NSF cer

fi

ed lubri

cant to all seals. 

3. This system is not intended for trea ng water that is microbiologically unsafe or of unknown 

quality without adequate disinfec on before or a er the system. 

Proud member of Canadian Institute of Plumb-

ing & Heating. 

Proud member of Canadian Water Quality Asso-

ciation. 

New Style Parallel Tank Connector 

Содержание 185HE SIMTAN

Страница 1: ...stalla on by applying provided with install kit NSF cer fied lubri cant to all seals 3 This system is not intended for trea ng water that is microbiologically unsafe or of unknown quality without adeq...

Страница 2: ...treating water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to mini...

Страница 3: ...s Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night...

Страница 4: ...ns and descriptions stated herein without obligation to change previously manufactured products or to note the change Specifica ons WG185SIMTAN10 WG185SIMTAN15 WG185SIMTAN20 WG185SIMTAN30 Purolite 850...

Страница 5: ...lops The manufacturer will not repair or pay for water damage A 120 volt electric outlet to plug the in cluded transformer into is needed within 6 feet of the softener The transformer has an attached...

Страница 6: ...of the parallel tank adaptor used in our dual tank products i e BIF BAF HTO HEDP etc has been redeveloped This new shorter version will also change the New flow directions OUT IN New Style Parallel Ta...

Страница 7: ...flows upwards in the tank 2 regenerating the media bed It then travels to tank 1 through the cen ter of the distribution tube and flows upwards in tank 1 and then out to the drain Settle Rinse During...

Страница 8: ...his could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or drain pipe This...

Страница 9: ...9 Installation...

Страница 10: ...for the full amount of time as dis played on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE position Open the outlet valve...

Страница 11: ...sage and capacity for the system For SIM units choose IRON MN WATER TYPE Select WELL OTHER if any Iron or Manganese is present or if the water source is not clean 1NUT turbidity The system will back w...

Страница 12: ...ll pause on the Date and Time page for 5 seconds Then it will continually scroll through all of the system diagnostic display pages Depending on the Valve Type some pages will not be dis played To man...

Страница 13: ...sometime during the night and manual regenerations should be performed when little or no water will be used in the household Normal regeneration time is 2 00 AM When the system capacity is near exhaus...

Страница 14: ...Use only crystal water softener salt Check the salt level monthly It is important to main tain the salt level above the water level To add salt simply lift the salt lid and add the salt directly into...

Страница 15: ...ontrol valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriver Re...

Страница 16: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Страница 17: ...ws is suggested when in stalling Sani System Liquid Sanitizer Concentrate Item 80030021 Softener Sanitizer 0 25 fl oz 24 Pack 1 Be sure to complete all installation steps including programming 2 For e...

Страница 18: ...t be used on a regular basis if your water supply contains iron The amount of resin cleaner and frequency of use is determined by the quantity of iron in your water consult your local representative o...

Страница 19: ...19 Blank Page...

Страница 20: ...20 Main Repair Parts Connectors A A A B D F E A C...

Страница 21: ...STON ASSEMBLY 60010035 INJECTOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032...

Страница 22: ...1 5030013 O Ring 30 2 65 A20 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1...

Страница 23: ...23 Power Head Exploded View...

Страница 24: ...Drive Gear B08 1 13000426 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magn...

Страница 25: ...25 Trouble Shooting...

Страница 26: ...26 Blank Page...

Страница 27: ...27 Blank Page...

Страница 28: ...t mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operated in accordance with specifications and n...

Отзывы: