CHAPTER 1:

INTRODUCTION TO THE 400ES SERIES DIGITAL INDICATORS

The 400ES Series Digital Indicator is a general purpose, industrial grade weight indicator
featuring keyboard tare and stainless steel enclosure. It can readout up to 50,000 display
divisions on its 0.56” tall LED display and can supply enough current for up to 4-350

load cells.

All setup parameters may be entered via the front panel keys, including calibration.

If your Model 400ES Series Digital Indicator is part of a complete floor scale or has been installed
for you, you may skip to Chapter 7 for operating instructions. Prior to using the indicator, please
read this chapter carefully and completely. Store the manual in a safe and convenient place so it
will be available if you have questions concerning the operation of the scale.

If you are an installer, the indicator's installation and wiring instructions are found in Chapter 2.
The indicator contains two main setup menus: The Setup (“F”) menu, which configures the
indicator to your weigh platform and the User (“A”) menu, which configures the serial
communication port and enables some user options. Chapter 3 gives an overview and explains
how to use the five front panel keys to maneuver and save settings in both menus. Chapters 4
and 5 explain the Setup and User Menu options, respectively. Chapter 6 covers system
calibration. Prior to installing the indicator, please read this manual carefully and completely.
Store the manual in a safe and convenient place so it will be available if you have questions
concerning the setup and operation of the scale.

DISP T

CLASS III

= 5,0 00

n

m a x

ZERO

NET

GROSS

TARE

lb

kg

MOTION

2

3

4

5

7

8

9

0

ZERO

NET

1

UNITS

TARE

6

GROSS

CAPACITY

400ES

T

SAVE

DISP T

PRINT

FIGURE 1-1: 400ES Front Panel

Your Model 400ES Digital Indicator contains a feature that allows you to print the current date on
the print ticket. This date is not stored or updated by the instrument and must be re-entered each
day.

To enter the date to be printed using the Date Entry procedure:

1. Ensure that A6 is set to Gross/Net/Tare print mode. See Chapter 3 for more information.

2. Remove power from the indicator, then re-apply power without holding down any keys.

3. The indicator will count down from all 6’s to all 1’s then will start to display dashes across the

screen one at a time from right to left.

4. BEFORE ALL SIX DASHES ARE DISPLAYED, use the front panel numeric keys to key-in the

desired date as you want it to appear in the printout. If you do not enter the first digit of the
date in time, simply start over from Step # 2. If you make a mistake entering the date, you may
use the

ZERO

key as a backspace key.

5.

After entering the desired date, press the

NET/GROSS

key to save the value. The indicator

does not check for a valid date and resumes Normal Operating Mode.

Содержание 400 Series

Страница 1: ...e 29 2005 1999 2005 Salter Brecknell Inc Contents subject to change without notice Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont MN 56031 Tel 800 637 0529 Tel 507 238 8702 Fax 507 2...

Страница 2: ...the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual may...

Страница 3: ...4 Exiting the Setup Menu 3 2 3 3 User A Menu 3 3 3 3 1 Entering the User Menu 3 3 3 3 2 Navigating in the User Menu 3 3 3 3 3 Notes on the User Menu 3 4 3 3 4 Exiting the User Menu 3 4 Chapter 4 Setu...

Страница 4: ...7 3 5 Entering an ID number 7 4 Chapter 8 Legal for Trade Sealing 8 1 8 1 Stainless Steel Enclosure 8 1 Appendix A Specifications A 1 Appendix B Serial Port Information B 1 B 1 Serial Port Modes B 1 B...

Страница 5: ...Terminal newer units 2 2 3 1 Setup Menu Key Assignments 3 2 3 2 Setup Menu Chart 3 2 3 3 User Menu Key Assignments 3 3 3 4 User Menu Chart 3 4 7 1 400ES LED Display Detail 7 1 7 2 Function Keys Layout...

Страница 6: ...ons respectively Chapter 6 covers system calibration Prior to installing the indicator please read this manual carefully and completely Store the manual in a safe and convenient place so it will be av...

Страница 7: ...he weigh platform printer remote display and power supply To remove the rear cover simply remove the screws that secure it to the enclosure and set aside NOTE The rear cover must remain off to access...

Страница 8: ...this is realized in J3 Connection assignments for all serial communication terminals are shown in Figure 2 3 NOTE Do not connect any RS 232 equipment to the 5V terminal 1 Connect your serial printer...

Страница 9: ...cate that you are in Setup Menu mode Note 1 Access to the back cover is inhibited if the indicator has been sealed for commercial use For more information please refer to Chapter 8 Note 2 If your indi...

Страница 10: ...Band 0d 2 1d 9d 1 2 5 F10 Dec Pt F17 Span Calib Press 2 key to begin F18 Cal View F19 Key in Zero Press 2 key to begin Press 2 key to begin F20 Key in Span Press 2 key to begin 0 0 0 0 00 0 000 0 0000...

Страница 11: ...r 3 When the indicator shows A 1 you are in User Menu mode and you may release the lb kg key 3 3 2 NAVIGATING IN THE USER MENU Use the directional keys shown in Figure 3 3 to move around in the User M...

Страница 12: ...A11 Print Header 0 1 0 1 Figure 3 4 User Menu Chart 3 3 3 NOTES ON THE USER MENU 1 Detailed descriptions of the user menu parameters can be found in Chapter 5 of this manual 2 Menus A10 and A11 appea...

Страница 13: ...still to automatically zero Selections are in Display Divisions 0d 0 5d 1d 3d 5d F4 Zero Range Selects the range within which the scale may be zeroed Note that the indicator must be in standstill to z...

Страница 14: ...fter Calibration F16 F17 has been successfully completed Scrolling down with the 2 key one level begins the procedure Press 2 key to begin sequence F19 Key in Zero Allows you to key in known zero cali...

Страница 15: ...cimal points and LCD annunciators in a test sequence Pressing the 2 key to scroll down one level begins the test sequence Press 2 key to begin sequence A5 Disable the lb kg Key Allows the lb kg key to...

Страница 16: ...ent ID number value 3 Use the front panel numeric keys to key in the actual ID number value If you make a mistake press the ZERO key to clear your entry and start over 4 After setting the exact value...

Страница 17: ...this time proceed to the F17 span calibration to complete indicator calibration 6 3 SPAN CALIBRATION F17 1 While in the Setup mode scroll to F 17 then scroll down once using the 2 key to enter span ca...

Страница 18: ...roll down once using the 2 key The display will momentarily show ET C 0 followed by a value of zero 2 Use the front panel keys to key in the actual zero calibration value If you make a mistake press t...

Страница 19: ...ive whenever the displayed weight is within 0 25 divisions of true zero NET Denotes that the indicator is displaying net weight GROSS Denotes that the indicator is displaying gross weight TARE Indicat...

Страница 20: ...d in F4 of the Setup F Menu 3 The scale is not in motion 4 The scale is not in overload see Appendix D for error codes This key also acts as a backspace key during numeric entry Net Gross This key tog...

Страница 21: ...r object is known you may enter this weight via the keyboard This value must be rounded to the nearest scale division For example on a 100 x 0 02 lb scale you must enter the tare weight value to the n...

Страница 22: ...the print ticket If you wish instead to key in a new ID Number each time a ticket is printed you may follow the procedure below before pressing the 0 PRINT key 1 Use the numeric keys to enter the new...

Страница 23: ...he rear cover of the indicator locate the calibration switch cover 3 Thread a wire security seal through both drilled head screws securing the calibration switch cover as well as the two drilled head...

Страница 24: ...C 32K x 8 internal to C SRAM 256 x 8 internal to C EEPROM 64 x 16 external to C SERIAL COMMUNICATIONS Serial Port Full Duplex 1200 2400 4800 9600 19200 Baud 8 data bits no parity 1 stop bit 7 data bi...

Страница 25: ...s a suggested cable diagram for interface to a PC Figure B 2 shows the serial data format for the Demand Mode INDICATOR PC 2 RXD RXD 2 TXD 3 S GND 5 3 TXD 5 S GND 6 DSR 4 DTR 8 CTS DSUB9 DSUB9 FIGURE...

Страница 26: ...will not respond if the scale is in motion positive overload or negative overload The indicator will also not respond if it is not in gross mode or a tare has yet to be established C This command is s...

Страница 27: ...g The transmission occurs at the end of each display update Figure B 5 shows the serial data format for Continuous Mode STX POL xxxxx xx L K G N STAT CR LF Polarity SP Positive Negative Weight Data Un...

Страница 28: ...umber closest to your full scale input range in millivolts 2 Enter the Setup Menu and save this number for the Span Gain parameter in F2 3 Perform a system calibration If the calibration proves unsucc...

Страница 29: ...2 500 150 75 50 50 25 25 25 25 25 25 25 25 25 25 25 3 000 150 75 50 50 50 25 25 25 25 25 25 25 25 25 25 4 000 200 100 75 50 50 50 50 25 25 25 25 25 25 25 25 5 000 150 100 75 50 50 50 50 50 25 25 25 25...

Страница 30: ...ons Use F16 mode to view internal counts See Appendix C for more information Err 3 All Modes Non volatile memory read error One or more setup parameters have been lost Err 4 All Modes Non volatile mem...

Отзывы: