53
English
System restart delay time
11.2. System impedance tables
System impedances for 3~400 V, 2‑pole, direct starting
Power
System impedance
Connections/h
kW
ohms
2.2
0.257
12
2.2
0.212
18
2.2
0.186
24
2.2
0.167
30
3.0
0.204
6
3.0
0.148
12
3.0
0.122
18
3.0
0.107
24
4.0
0.130
6
4.0
0.094
12
4.0
0.077
18
5.5
0.115
6
5.5
0.083
12
5.5
0.069
18
7.5
0.059
6
7.5
0.042
12
9.0 – 11.0
0.037
6
9.0 – 11.0
0.027
12
15.0
0.024
6
15.0
0.017
12
System impedances for 3~400 V, 2‑pole, star‑delta starting
Power
System impedance
Connections/h
kW
ohms
5.5
0.252
18
5.5
0.220
24
5.5
0.198
30
7.5
0.217
6
7.5
0.157
12
7.5
0.130
18
7.5
0.113
24
9.0 – 11.0
0.136
6
9.0 – 11.0
0.098
12
9.0 – 11.0
0.081
18
9.0 – 11.0
0.071
24
15.0
0.087
6
15.0
0.063
12
System impedances for 3~400 V, 2‑pole, star‑delta starting
Power
System impedance
Connections/h
kW
ohms
15.0
0.052
18
15.0
0.045
24
18.5
0.059
6
18.5
0.043
12
18.5
0.035
18
22.0
0.046
6
22.0
0.033
12
22.0
0.027
18
11.3. Spare parts
Spare parts can be ordered from Salmson Customer Service.
To avoid queries and incorrect orders, the serial and/or article
number must always be stated.
Subject to change without prior notice