1. General

1.1   About this document

The  language  of  the  original  operating  instruc-
tions  is  French.  All  other  languages  of  these
instructions are translations of the original oper-
ating instructions.
These  installation  and  operating  instructions  are
an integral part of the product. They must be kept
readily available at the place where the product is
installed. Strict adherence to these instructions is
a  precondition  for  the  proper  use  and  correct
operation of the product.
These installation and operating instructions cor-
respond  to  the  relevant  version  of  the  product
and  the  underlying  safety  standards  valid  at  the
time of going to print.
EC declaration of conformity: 
A  copy  of  the  EC  declaration  of  conformity  is  a
component of these operating instructions. 
If a technical modification is made on the designs
named there without our agreement, this decla-
ration loses its validity.

2. Safety

These operating instructions contain basic infor-
mation which must be adhered to during installa-
tion, operation and maintenance. For this reason,
these operating instructions must, without fail, be
read by the service technician and the responsible
specialist/operator  before  installation  and  com-
missioning.
It is not only the general safety instructions listed
under  the  main  point  “safety”  that  must  be
adhered to but also the special safety instructions
with danger symbols included under the following
main points.

2.1  Symbols and signal words in the operating

instructions

Symbols:

General danger symbol.

Danger due to electrical voltage.

NOTE: ....

Signal words:

DANGER! Acutely dangerous situation.
Non-observance  results  in  death  or  the  most
serious of injuries.

WARNING! The user can suffer (serious) injuries.
'Warning' implies that (serious) injury to persons
is probable if this information is disregarded.

CAUTION! There is a risk of damaging the
product/unit. “Caution” implies that damage to
the product is likely if this information is disre-
garded.

NOTE: Useful information on handling the product.
It draws attention to possible problems. Information
that appears directly on the product, such as

•  Direction of rotation arrow,
•  Identifiers for connections,
•  Name plate,

•  Warning sticker

must be strictly complied with and kept in legible
condition.

2.2  Personnel qualification

The installation, operating and maintenance per-
sonnel  must  have  the  appropriate  qualifications
for this work. Area of responsibility, terms of ref-
erence and monitoring of the personnel are to be
ensured by the operator. If the personnel are not
in  possession  of  the  necessary  knowledge,  they
are  to  be  trained  and  instructed.  This  can  be
accomplished if necessary by the manufacturer of
the product at the request of the operator.

2.3  Danger in the event of non-observance of the

safety instructions

Non-observance  of  the  safety  instructions  can
result  in  risk  of  injury  to  persons  and  damage  to
the  environment  and  the  product/unit.  Non-
observance  of  the  safety  instructions  results  in
the loss of any claims for damages.
In  particular,  non-observance  can,  for  example,
result in the following risks:

•  Danger to persons from electrical, mechanical

and bacteriological influences,

•  Damage to the environment due to leakage of

hazardous materials,

•  Property damage,
•  Failure of important product/unit functions,
•  Failure of required maintenance and repair procedures.

2.4  Safety consciousness on the job

The  safety  instructions  included  in  these  installa-
tion and operating instructions, the existing nation-
al regulations for accident prevention together with
any internal working, operating and safety regula-
tions of the operator are to be complied with.

2.5  Safety instructions for the operator

This appliance is not intended for use by persons
(including children) with reduced physical, senso-
ry or mental capabilities, or lack of experience and
knowledge, unless they have been given supervi-
sion  or  instruction  concerning  use  of  the  appli-
ance  by  a  person  responsible  for  their  safety.
Children should be supervised to ensure that they
do not play with the appliance.

•  If hot or cold components on the product/the

unit lead to hazards, local measures must be
taken to guard them against touching.

•  Guards protecting against touching moving com-

ponents (such as the coupling) must not be
removed whilst the product is in operation.

•  Leakages (e.g. from the shaft seals) of hazardous

fluids (which are explosive, toxic or hot) must be
led away so that no danger to persons or to the
environment arises. National statutory provisions
are to be complied with.

•  Highly flammable materials are always to be kept

at a safe distance from the product.

•  Danger from electrical current must be eliminat-

ed. Local directives or general directives [e.g. IEC,
VDE etc.] and local power supply companies
must be adhered to.

Содержание PRIMA DRAIN

Страница 1: ...N M S STOCK N 4152291 Ed02 08 14 PRIMA DRAIN INSTALLATION ET MISE EN SERVICE INSTALLATION AND STARTING INSTRUCTIONS FRANÇAIS ENGLISH ...

Страница 2: ......

Страница 3: ......

Страница 4: ...Fig 1 B min 1 230V 1 230V 50 Hz h1 h h2 ...

Страница 5: ...fr Installation et mise en service 6 en Installation and operating instructions 11 ...

Страница 6: ...hes indiquant le sens de rotation le marquage des raccords la plaque signalétique les autocollants d avertissement doivent être impérativement respectées et maintenues dans un état bien lisible 2 2 Qualification du personnel Il convient de veiller à la qualification du personnel amené à réaliser le montage l utilisation et l entre tien L opérateur doit assurer le domaine de res ponsabilité la comp...

Страница 7: ...ns un endroit sec et protégez le contre les chocs et toutes influences extérieures humidité gel etc 4 Produit et accessoires 4 1 Applications Les pompes submersibles pour eaux usées sans matières fécales et de drainage PRIMA DRAIN sont utilisées pourvidangerautomatiquementlesfossesetlescuves pour garder au sec les caves et les cours présen tant des risques d inondation pour faire baisser l eau de ...

Страница 8: ...illance de la première pompe 6 Montage et raccordement électrique DANGER Un montage et un raccordement électrique incorrects peuvent être dangereux pour la santé Le montage et le raccordement électrique doi vent être effectués par un électricien agréé conformément aux prescriptions locales en vigueur Respecter les consignes de prévention des acci dents S assurer que l installation électrique génér...

Страница 9: ...t de commande doivent être protégés contre les inondations et installés dans un local sec 7 Mise en service DANGER Risque d électrocution Il est interdit d utiliser la pompe pour vidanger les piscines bassin de jardin ou endroits similaires lorsqu il y a des personnes dans l eau ATTENTION Risques de dommages matériels La pompe ne doit jamais fonctionner à sec Ceci endommagerait fortement les bague...

Страница 10: ...protection thermique moteur s est déclenchée Laisser refroidir la pompe redémarrage automatique Température du fluide véhiculé trop éle vée Laisser refroidir Pompe ensablée ou bloquée Débrancher la pompe du secteur et la soulever hors de la cuve Rincer la crépine d aspiration la roue sous l eau courante La pompe ne s enclenche pas ne s arrête pas L interrupteur à flotteur est bloqué ou ne bouge pa...

Страница 11: ...ication The installation operating and maintenance per sonnel must have the appropriate qualifications for this work Area of responsibility terms of ref erence and monitoring of the personnel are to be ensured by the operator If the personnel are not in possession of the necessary knowledge they are to be trained and instructed This can be accomplished if necessary by the manufacturer of the produ...

Страница 12: ...ste water except rigid particles pumps are used for the automatic drainage of pits and shafts for keeping dry yard areas and basement rooms exposed to flooding for lowering surface water if the waste water is not able to flow off into the sewer system through natural fall The pumps are suitable for pumping slightly con taminated water rainwater drainage water and washing water The pumps are usuall...

Страница 13: ...rth fault breaker max 30 mA The electrical connections have to be done before the pump is lowered into the sump Check that the type voltage and frequency of the electric line power supply complies with the indi cations mentioned on the name plate The pump is delivered with a 3 wires cable equipped with a standardised plug 2 poles earth Connect obligatory the cable on a socket with 2 pole earth 6 1...

Страница 14: ...alve on the pressure side if provided the pump starts up automatically when the switch on level h is reached and switches off as soon as the switch off level h1 responds Do not direct the jet of water to be fed into the shaft at the suction strainer of the pump Entrained air can prevent the operating pump from functioning if the vent slit in the housing is blocked The maximum volume of water enter...

Страница 15: ...r run ning water Pump does not switch ON OFF Float switch blocked or cannot move freely Check float switch and ensure mobility Pump does not pump Air in the installation cannot escape Place the pump at an angle in water brie fly until the air escapes Vent the installation drain if necessary Clean the degasification hole located on the pump housing Check the switch off level h1 Water level below th...

Страница 16: ...JOURS DISPONIBLE SUR SITE Ce produit a été fabriqué sur un site certifié ISO 14 001 respectueux de l environnement Ce produit est composé de matériaux en très grande partie recyclable En fin de vie le faire éliminer dans la filière appropriée SALMSON SOUTH AFRICA 13 Gemini street Linbro Business Park PO Box 52 STANTON 2065 Republic of SOUTH AFRICA TEL 27 11 608 27 80 1 2 3 FAX 27 11 608 27 84 admi...

Отзывы: