9
CONNECTING TO POWER
The oven is provided with a three-pole power cable with free terminals.
If the oven is connected permanently to the mains, install a device ensuring disconnection from the
mains, with a contact opening distance (of at least 3 mm) that allows complete disconnection in the
conditions of overvoltage category III. Check that:
a) The plug and socket are suitable for a current of 16°
b) Both are within easy reach and placed so that no live part can be accessed while plugging in or
unplugging
c) The plug can be inserted without difficulty
d) Once the plug has been inserted, the oven does not rest on it when it is installed in the cabinet
e) The terminals of two appliances are not connected to the same plug
f) If changing the power cable, use one with 3 x 1.5mm specifications 2 type H05VV-F or H05RR-F
g) It is essential that the coupling polarities of the free terminals are respected (Brown = Live; Blue =
Neutral; Yellow-Green = Earth).
IMPORTANT:
Make sure the characteristics of your household electrical power supply (voltage, maxi-
mum power and current) are compatible with those of the appliance.
LIVE
NEUTRAL
EARTH
The system must have an earthing wire, distinguished
by the yellow-green colour of the protective sleeve.
MOUNTING
1) Insert the appliance into the allocated cabinet space.
2) Fix the body to the cabinet with the 2 screws provided using the holes in the upper profile of oven.