8
| EN
AMBERAIR COMPACT RH v2019.08
METAL IMPELLER
7 RH F1 E1
5,00
8
3~ / 400
27
39,02
3~ / 400
32,5 / 50,02
7 RH F1 E2
5,00
8
3~ / 400
30
43,36
3~ / 400
35,5 / 54,36
7 RH F1 E3
5,00
8
3~ / 400
51
73,71
3~ / 400
56,5 / 84,71
7 RH F1 W
5,00
8
3~ / 400
0,8
3,48
1~ / 400
6,3 / 14,48
7 RH F2 E1
7,20
11,6
3~ / 400
27
39,02
3~ / 400
34,7 / 53,62
7 RH F2 E2
7,20
11,6
3~ / 400
30
43,36
3~ / 400
37,7 / 57,96
7 RH F2 E3
7,20
11,6
3~ / 400
51
73,71
3~ / 400
58,7 / 88,31
7 RH F2 W
7,20
11,6
3~ / 400
0,8
3,48
1~ / 400
8,5 / 18,08
7 RH F3 E1
7,20
11,8
3~ / 400
27
39,02
3~ / 400
34,7 / 53,82
7 RH F3 E2
7,20
11,8
3~ / 400
30
43,36
3~ / 400
37,7 / 58,16
7 RH F3 E3
7,20
11,8
3~ / 400
51
73,71
3~ / 400
58,7 / 88,51
7 RH F3 W
7,20
11,8
3~ / 400
0,8
3,48
1~ / 400
8,5 / 18,28
7 RH F4 E1
14,40
23,2
3~ / 400
27
39,02
3~ / 400
41,9 / 65,22
7 RH F4 E2
14,40
23,2
3~ / 400
30
43,36
3~ / 400
44,9 / 69,56
7 RH F4 E3
14,40
23,2
3~ / 400
51
73,71
3~ / 400
65,9 / 99,91
7 RH F4 W
14,40
23,2
3~ / 400
0,8
3,48
1~ / 400
15,7 / 29,68
7RH FILTER DATA
Filter code
Type
Width, [mm] Height, [mm] Depht, [mm] Bag nr.
Class*
Efficiency*
Filtras FMK 592x490x350-7/F9
Bag filter
592
490
350
7
ePM1
85
Filtras FMK 592x490x350-7/M5
Bag filter
592
490
350
7
EePM10
60
Filtras FMK 592x490x350-7/SGF7
Bag filter
592
490
350
7
ePM1
70
Filtras FMK 592x490x570-8/F9
Bag filter
592
490
570
8
ePM1
85
Filtras FMK 592x490x570-8/M5
Bag filter
592
490
570
8
EePM10
60
Filtras FMK 592x490x570-8/SGF7
Bag filter
592
490
570
8
ePM1
70
Filtras MPL 592x490x46 F7
Panel filter
592
490
46
-
ePM1
70
Filtras MPL 592x490x46 F9
Panel filter
592
490
46
-
ePM1
85
Filtras MPL 592x490x46 M5
Panel filter
592
490
46
-
EePM10
65
Filtras MPL 592x490x46 G4
Panel filter
592
490
46
-
Coarse 85
50
* - according to ISO 16890.
4.4. OPERATING CONDITIONS
PLACE OF OPERATION
INDOORS / OUTDOORS / INDOORS AND OUTDOORS /
OUTDOORS WITH SPECIAL ACCESSORIES
Operation in explosive environment
prohibited
Transporting of the polluted air
prohibited
Outdoor air temeperature without preheater
-23/+40
°C
Outdoor air temperature limits with a selected pre-heater on an air duct
-40/+40
°C
Outdoor air max humidity
90
%
Temperature limits of an extracted air
+15 / +40
°C
Extract air max humidity
60
%
Maximum room temperature for installing the unit
0 / +40
°C
The air handling units installed outdoors shall be started only when the following obligatory conditions established by the manufacturer are met:
• Units that are stored at the site before installation shall be sealed using additional means in order to prevent the accumulation of moisture inside
the unit.
• If the unit is installed and is not started for continuous operation, it must be ensured that no warm/humid air enters the unit through air ducts
and that no moisture condensates inside the unit.
• If the ventilation units stand idle for a long time or are started infrequently, the system must be blown down at the maximum capacity 1/24 h to
dehumidify.
•
Voltage to the automatics of the unit is installed and connected; the system of water products is filled with glycol/water.
In case of failure to comply with the requirements set out above, the manufacturer shall have the right not to refute the warranty in respect of the
occurrence of moisture/water in damaged components.