12. WARRANTY

1. All equipment manufactured in our factory is checked in operating conditions and tested befor delivery. Test protocol is supplied together with 

the unit. The equipment is shipped in good working order and condition to the direct client. The unit is warrantied for the period of two years from 

the invoice date.

2. If equipment is found to have been damaged during transportation, a claim should be made against carrier, as we assume no responsibility for 

such damage.

3. This warranty does not apply:

3.1. when transportation, storage, installation and maintenance instructions of the unit are violated;

3.2. when the equipment is improperly maintained, mounted - inadequate maintenance; 

3.3. when the equipment without our knowledge and permission has been upgraded or unskilled repairs were made;

3.4. when the unit was used not for its original purpose.

3.5. Company SALDA UAB is not responsible for potential loss of property or personal injury in cases where AHU is manufactured without a 

control system and the control system will be installed by the client or third parties. The manufacturer’s warranty does not cover devices that 

will be damaged by installing the control system.

4. This warranty does not apply at these malfunction cases:

4.1. mechanical damage; 

4.2. damage caused by entering outside objects, materials, liquids; 

4.3. damage caused by natural disaster, accident (voltage change in the electricity network, lightning, etc..).

5. The company assumes no liability for its products either directly or indirectly damage, if the damage is caused by failure to comply with instal-

lation and mounting regulations, deliberate or careless users or third-party behavior.

These conditions are readily discernable when the equipment is returned to our factory for inspection.

If the direct client determines that equipment is found to be faulty, or a breakdown occurred, he should inform the manufacturer within five working 

days and deliver the equipment to manufacturer. Delivery costs should be covered by customer.

Manufacturer reserves the right to change this technical passport any time without prior notice, if some typographic 

errors or inaccurate information is found, as well as after improving the apps and/or the devices. Such changes will be 

included in the new issues of the technical passport. All illustrations are just for information and thus may differ from the 

original device.

12.1. LIMITED WARRANTY COUPON

Warranty term

24 months*

I received complete package and technical manual of the product ready for usage. I have read warranty terms and conditions and agree with them: 

 

..........................................................................................................................................................................

Customer’s signature

*refer to WARRANTY CONDITIONS

D

ear User, we appreciate your choice and do hereby guarantee that all ventilation equipment manufactured by our Company is inspected and 

thoroughly tested. An operational and high-quality product is sold to the direct buyer and shipped from the territory of the factory. It is provided with 

a 24-month warranty since invoice issue date.

Your opinion is important to us, thus we always look forward to hearing your comments, feedback, or suggestions regarding technical and opera

-

tional characteristics of the Products.

In order to avoid any misunderstandings, please read the instructions for installation and operation of the product as well as other technical docu

-

ments of the product carefully. The number of the Limited Warranty Coupon and serial number of the product specified on the silver identification 

sticker attached to the housing must match. 

The Limited Warranty Coupon shall be valid provided that the seller’s stamps and records are clear. It is prohibited to change, delete, or rewrite 

the data specified on it in any manner – such a coupon shall be invalid.

With this Limited Warranty Coupon the manufacturer confirms one’s obligations to implement the imperative requirements established by effective 

laws on protection of consumer rights in the event of identification of any defects of the products.

The manufacturer reserves the right to refuse provision of free warranty servicing in cases when the warranty conditions listed below are disre

-

garded.

Содержание AMBERAIR COMPACT 7 RH E

Страница 1: ...AMBERAIR COMPACT RH EN MOUNTING AND INSTALLATION INSTRUCTION...

Страница 2: ...7 5 8 1 SYSTEM PROTECTION 17 5 8 2 PRE STARTUP RECOMENDATIONS OF THE UNIT IN THE PRESENCE OF THE ENDUSER 17 6 MAINTENANCE 17 6 1 SAFETY INSTRUCTION 17 6 2 COVER OPENING 17 6 3 FILTERS AND PREFILTER MA...

Страница 3: ...ation and air conditioning systems and units SALDA world like to inform you that based on the Commission Regulation EU No 1253 2014 for enforcing directive 2009 125 EC hereinafter referred to as ErP d...

Страница 4: ...ng transportation and installation Make sure not to damage the heater when connecting the piping of the water heater For tightening up use a wrench spanner Before starting the equipment make sure that...

Страница 5: ...ess and coating options 0 7 mm AluZn 185 0 5 mm Zn polyester painting RAL 7040 0 7 mm AluZn 185 0 5 mm Zn polyester painting RAL 7040 Internal sheet metal thickness and coating options 0 7 mm AluZn 18...

Страница 6: ...n special groove 7 panel block aluminium profile 8 panel block gasket Figure 4 1 1 4 AmberAir Compact SD50 cross section 1 Corner profile with thermal break strips 2 intermediate profile with thermal...

Страница 7: ...8 3 400 30 43 36 3 400 35 5 54 36 7 RH F1 E3 5 00 8 3 400 51 73 71 3 400 56 5 84 71 7 RH F1 W 5 00 8 3 400 0 8 3 48 1 400 6 3 14 48 7 RH F2 E1 5 80 9 6 3 400 27 39 02 3 400 33 3 51 62 7 RH F2 E2 5 80...

Страница 8: ...lter 592 490 46 ePM1 85 Filtras MPL 592x490x46 M5 Panel filter 592 490 46 EePM10 65 Filtras MPL 592x490x46 G4 Panel filter 592 490 46 Coarse 85 50 according to ISO 16890 4 4 OPERATING CONDITIONS PLACE...

Страница 9: ...6 11 15 10 14 9 13 20 19 18 17 1 supply air fan 2 supply air fan pressure sensor on control board 3 extract air fan 4 extract air fan pressure sensor on control board 5 supply air filter 6 supply air...

Страница 10: ...ers Enthalpy width 200 mm il rot E E20 1900 ZSLROET0007 il rot E E16 1900 ZSLROET0008 il rot E E20 1700 ZSLROET0009 il rot E E16 1700 ZSLROET0010 il rot E E20 1500 ZSLROET0011 il rot E E16 1500 ZSLROE...

Страница 11: ...utiklis temp TJ1TE NTC10k3 6x6x22B 2x5 0 m PVC PJUT0069 Temperaturos jutikliui TJ1 NTC10k3B 6x240S 2x2 0mPVC CF PJUT0076 5 INSTALATION 5 1 RECEPTION OF GOODS Each device is thoroughly checked before t...

Страница 12: ...ith slings it is necessary to insert spacers between them in order to prevent damage to the casing of the product Figure 5 2 2 AmberAir Compact lifting with slings 5 3 UNPACKING Remove the film from t...

Страница 13: ...ed from the pallet with a forklift at the recesses at the supporting base or with slings 5 4 MOUNTING DIAGRAM TV1_P TV1_I T2 TV1_P TV1_I Figure 5 4 1 With automatic TV1_P TV1_I T2 TV1_P TV1_I Figure 5...

Страница 14: ...Water heater temperature sensor P on the pipe I into the pipe CW2 Duct Water cooler TV2_P TV2_I Duct Water heater cooler temperature sensor P on the pipe I into the pipe DX2 DX cooler 5 5 MOUNTING In...

Страница 15: ...sportation and Storage Note Before conecting sections please remove transportation rubber tapes from rotor wheel Extended rotor section connection 5 5 1 PLACE REQUIREMENTS FOR THE EQUIPMENT AND MOUNTI...

Страница 16: ...n fixing Make sure that the fans can not be accessed through air duct heads If it is possible to access the fan protective grid should be installed You can choose it in our website Do not reduce the d...

Страница 17: ...twork After installation of the ventilation unit disconnection from the power network is performed through the external protection device and unit main switch The unit must be thoroughly checked again...

Страница 18: ...Before starting maintenance or repair work make sure that the unit is disconnected from the electrical network and main switch is turned off Maintenance should be performed only by experienced and tra...

Страница 19: ...release the retainers The fan unit is pulled out through the slide rails It is recommended to use a lifting hook for lifting the fan unit from the product Use the provided lifting holes If there is a...

Страница 20: ...doors of the product Unscrew the switchboard from the control section Disconnect the connections from the controller Remove the controller To reassemble repeat the actions in the reverse order When co...

Страница 21: ...ote control connector BMS connection Date and time settings Manual components control System modes for easy end user control Stand by building protection economy comfort Air flows are used in the syst...

Страница 22: ...control Water heater protection thermostat NC Water heater circulation pump control Water heater protection temperature sensor Water cooler 0 10V valve control Water cooler circulation pump control Wa...

Страница 23: ...scription of the acquired air handling system 3 Internal components of the device type of heat exchanger plate or rotor integrated dampers sensors and etc see components of the chosen device 4 Control...

Страница 24: ...ator NM230A TP ZAKP0055 Damper actuator with spring NFA ZAKP0051 Thermostat T Anti frost spiral TS1C0P ZAKT0009 Thermostat T 20 90 C 16A 250V Thermostat 20 90 C 16A 250V ZAKT0013 Pressure relay PS600B...

Страница 25: ...x stogelis Comfort Box roof RCB 1747x967 GNGPR168_1252_0 Water cooler RWC 1753x973 C2 GNGPR168_1239_0 RWC 1753x973 C4 GNGPR168_1253_0 Water cooler mounting legs for bottom chanel LRWC 1753x973 GNGPR16...

Страница 26: ...7x967 L HW1 CDX2 DE GSIASD0108 CB 1747x967 L HW1 CDX4 DE GSIASD0109 CB 1747x967 L HW2 CW2 DE GSIASD0110 CB 1747x967 L HW2 CW4 DE GSIASD0111 CB 1747x967 L HW2 CDX2 DE GSIASD0112 CB 1747x967 L HW2 CDX4...

Страница 27: ...onnection 7 E1 E2 E3 C2 Electrical connection when E3 heater and C2 control SP90 E3 elektrical heater 51kW 7 IVS F1 F2 F3 Extract air fan F1 F2 F3 TE and TL SP92 Duct electrical heater 126kW 7 IVS F4...

Страница 28: ...L3 N PE POWER SUPPLY 3 400V 50Hz Xp1 PE 230 MAIN SWITCH 55 1 N 62 62 230 Q1 1 2 3 4 5 6 7 8 55 SAF Fan Q3 L1 Heater Q5 L1 Heater Q6 L1 EAF Fan Q4 L1 Control Q2 2 L1 Heater Q5 L2 Heater Q6 L2 Heater Q...

Страница 29: ...3 400V 50Hz Xp1 PE 230 2 MAIN SWITCH 55 1 N 62 62 230 2 Q1 1 2 3 4 5 6 7 8 55 SAF Fan Q3 L1 Heater Q5 L1 Heater Q6 L1 EAF Fan Q4 L1 Control Q2 2 L1 Heater Q5 L2 Heater Q6 L2 Heater Q5 L3 Heater Q6 L3...

Страница 30: ...SUPPLY 3 400V 50Hz Xp1 PE 02 1 MAIN SWITCH 55 1 N 62 62 02 1 Q1 1 2 3 4 5 6 7 8 55 SAF Fan Q3 L1 Heater Q5 L1 Heater Q6 L1 EAF Fan Q4 L1 Control Q2 2 L1 Heater Q5 L2 Heater Q6 L2 Heater Q5 L3 Heater Q...

Страница 31: ...rminal block Control box Rotor Motor Controller 1 2 3 1 2 3 10 8 9 1 2 L N PE 0 10V GND RL_C RL_NC RL_NO OJ DRHX M3 L1 R 1 2 N 1 2 PE 1 2 31 1 2 32 1 2 33 1 2 34 1 2 AHU 1 41 2 1 40 2 1 39 2 1 38 2 1...

Страница 32: ...r temp sensor 1 2 3 4 5 6 X102 769 112 7 8 9 10 11 12 W19 white W19 brown W18 white W18 brown ODA EHA TL TE Extract air fan 1 1 2 3 4 5 6 1 480704 0 X35 Extract air fan 1 1 2 3 4 5 6 X101 769 112 7 8...

Страница 33: ...A EHA TL TE Extract air fan 1 Extract air fan 1 1 2 3 4 5 6 EX2 EHA X101 769 112 7 8 9 10 11 12 1 2 3 4 5 6 1 480704 0 X33 2 1 2 3 4 5 6 1 480704 0 X33 1 Extract air fan 2 1 2 3 4 5 6 1 480704 0 X35 1...

Страница 34: ...BY SIGNATURE DUTIES NAME DATE SALDA UAB Drawing Book APPROVED BY Revision 1 2 3 4 5 6 7 8 9 10 7RH 7 IVS PS 1X Principal connection scheme 1 11 2018 06 14 2018 06 14 0 PS1 1 COM 2 NO 3 NC X102 3 X102...

Страница 35: ...SALDA UAB Drawing Book APPROVED BY Revision 1 2 3 4 5 6 7 8 9 10 7RH 7 IVS PS 2X Principal connection scheme 1 09 2018 06 14 2018 06 14 0 PS1 2 1 COM 2 NO 3 NC X102 3 X102 4 PS1 1 1 COM 2 NO 3 NC X10...

Страница 36: ...11 12 W14 white W14 red W14 green SUP ETA W15 brown W15 white U RH TA GN YE RD WH GND RH 5V TA DTJ TR1 1 2 3 4 5 6 X100 769 112 7 8 9 10 11 12 W16 gr ye W16 gr ye W16 grey W16 brown W16 black W14 red...

Страница 37: ...6 1 480704 0 X32 2 1 2 3 4 5 6 1 480704 0 X34 1 1 2 3 4 5 6 1 480704 0 X34 2 W6 gr ye W7 black W6 black W7 brown W6 brown W7 grey W6 grey W7 gr ye W7 gr ye W7 grey W7 brown W7 black W6 black W6 brown...

Страница 38: ...ical heater 24 SUP 1 2 3 4 5 6 X5 769 112 7 8 9 10 11 12 1 2 3 4 5 6 X30 769 112 7 8 9 10 11 12 1 2 3 4 5 6 X29 769 112 7 8 9 10 11 12 1 2 3 4 5 6 X6 769 112 7 8 9 10 11 12 White 0 5 Black 4 White 0 5...

Страница 39: ...Y SIGNATURE DUTIES NAME DATE SALDA UAB Drawing Book APPROVED BY Revision 1 2 3 4 5 6 7 8 9 10 7RH 7 PVS PS 1X Principal connection scheme 1 10 2018 06 14 2018 06 14 0 PS2 1 COM 2 NO 3 NC X103 1 X103 2...

Страница 40: ...BY SIGNATURE DUTIES NAME DATE SALDA UAB Drawing Book APPROVED BY Revision 1 2 3 4 5 6 7 8 9 10 7RH 7 PVS T1 Principal connection scheme 1 08 2018 06 14 2018 06 14 0 X103 9 X103 10 1_COM 2_NO 4_NC PE...

Страница 41: ...3 4 5 6 X104 769 612 002 000 7 8 9 10 11 12 1 2 3 4 5 6 X104 769 112 7 8 9 10 11 12 156 153 150 135 132 147 144 141 138 123 121 119 117 115 113 129 126 96 99 102 105 108 111 RS 159 Brown 0 75 Green ye...

Страница 42: ...2 3 4 5 6 X100 X101 769 112 7 8 9 10 11 12 W3 black W3 gr ye W3 grey W3 brown RS 1 2 3 4 5 6 X102 X103 769 112 7 8 9 10 11 12 1 2 3 4 5 6 X102 X103 769 612 002 000 7 8 9 10 11 12 White 0 5 White 0 5...

Страница 43: ...3 4 5 6 7 8 9 10 7RH 7 VM 1 18 2018 06 14 2018 06 14 0 11 14 GND E1 24VDC D1 MOEA03K0 PVS IVS W20 grey W20 brown W20 black W20 gr ye PE L1 L2 L3 N MOEA03K0 1 2 3 4 5 6 Power 1 2 3 4 5 6 Control 10VDC...

Страница 44: ...L N PE V V PE 28 28 28 32 32 35 35 35 31 34 X15 KF2EDGKD 2 5 3P 3 2 1 87 K1 A1 A2 1 2 02 2 4 K1 41 41 K2 A1 A2 1 2 02 4 4 K2 43 43 43 Q1 1 2 3 4 5 6 7 8 PE PE 7 6 8 B 10 Q2 1 2 3 4 5 5 C 16 Q3 1 2 3 4...

Страница 45: ...T 219 1142 219 1142 0 1 2 PS 7 W C2 02 12 10 2018 12 10 2018 12 10 2018 1 25 PS 2 1 26 2 1 27 2 1 28 2 1 29 2 1 30 2 1 PE R 2 1 N 2 1 L1 2 1 31 2 1 32 2 1 33 2 1 34 2 1 35 KV 2 1 36 2 1 37 2 1 38 2 P...

Страница 46: ...1 9 2 1 10 2 1 11 2 1 12 2 1 13 TEMP 2 1 14 2 1 15 2 1 16 2 1 17 2 1 18 2 1 19 2 1 20 2 1 21 2 1 22 2 1 23 2 1 24 2 PE L1 L2 L3 24 D1 GND E1 11 14 PV1 PE L1 L2 L3 24 D1 GND E1 11 14 PV2 PE L1 L2 L3 2...

Страница 47: ...evision SIGNATURE 1 2 3 4 5 6 7 8 9 10 7RH IVS MODBUS 1X 1 17 0 dariusaleksandravici 2018 06 14 RS SUP EHA ETA ODA 1 2 3 U5 MB MCB U6 1 2 3 SL1 Switch 1 ON 120 Ohm 2 OFF 1 kOhm 3 OFF 1 kOhm J10 J20 J5...

Страница 48: ...ATURE 1 2 3 4 5 6 7 8 9 10 7RH IVS MODBUS 2X 1 16 0 dariusaleksandravici 2018 06 14 RS SUP EHA ETA ODA 1 2 3 U5 MB MCB U6 1 2 3 1 2 3 SL1 Switch 1 ON 120 Ohm 2 OFF 1 kOhm 3 OFF 1 kOhm J10 J16 J5 J10 J...

Страница 49: ...wing Book APPROVED BY Revision RSD Principal connection scheme 1 01 2018 06 14 2018 06 14 0 M3 1 2 3 1 2 3 10 8 9 1 2 L N PE 0 10V GND RL_C RL_NC RL_NO OJ DRHX 438 436 1 2 3 4 5 6 X51 7 8 9 794715 1 B...

Страница 50: ...63 63 57 59 61 1 2 3 4 5 6 X30 769 612 002 000 7 8 9 10 11 12 PE 54 58 57 58 5 9 9 43 34 34 43 49 49 TK2 64 TK1 47 47 60 3 4 3 4 5 EK9 A1 A2 EK8 A1 A2 EK7 A1 A2 K12 1 2 3 4 5 6 17 17 15 15 14 14 11 12...

Страница 51: ...3 4 5 6 K1 1 2 3 4 5 6 K1 A1 A2 230VAC 1 2 01 3 4 01 5 6 01 13 14 01 K1 K2 1 2 3 4 5 6 K2 A1 A2 230VAC 1 2 01 3 4 01 5 6 01 K2 STEP 1 3x2000W 3x3000W K3 1 2 3 4 5 6 STEP 3 3x1000W 9x3000W K3 A1 A2 23...

Страница 52: ...HEAT1 X26 X17 X14 N7 EKR KN3 NIS X25 COM X24 K1 X22 K2 X20 K3 X18 K4 X8 X10 X5 X6 X3 0 10V X4 GND N7 EKR KN3 NIS K11 1 2 3 4 5 6 2 2 7 7 1 8 8 53 53 52 52 51 51 K11 A1 A2 230VAC DO8 N 12VDC DI AT 63...

Страница 53: ...HEAT1 X26 X17 X14 N7 EKR KN3 NIS X25 COM X24 K1 X22 K2 X20 K3 X18 K4 X8 X10 X5 X6 X3 0 10V X4 GND N7 EKR KN3 NIS K11 1 2 3 4 5 6 2 2 7 7 1 8 8 53 53 52 52 51 51 K11 A1 A2 230VAC DO8 N 12VDC DI AT 63 6...

Страница 54: ...4 5 6 K1 1 2 3 4 5 6 K1 A1 A2 230VAC 1 2 01 3 4 01 5 6 01 13 14 01 K1 K2 1 2 3 4 5 6 K2 A1 A2 230VAC 1 2 01 3 4 01 5 6 01 K2 STEP 1 6x2000W K3 1 2 3 4 5 6 STEP 3 3x1000W 6x2000W K3 A1 A2 230VAC 1 2 01...

Страница 55: ...2 1 2 3 4 5 6 K2 A1 A2 230VAC 1 2 01 3 4 01 5 6 01 K2 34 34 36 36 38 38 35 35 33 33 37 37 31 32 31 32 STEP 1 3x3000W K3 1 2 3 4 5 6 47 41 44 44 48 48 45 45 42 42 41 47 40 39 40 39 STEP 3 3x1000W 6x200...

Страница 56: ...5 6 K2 A1 A2 230VAC 1 2 01 3 4 01 5 6 01 K2 31 31 33 33 35 35 32 32 30 30 34 34 28 29 28 29 STEP 1 3x3000W K3 1 2 3 4 5 6 42 38 40 40 44 44 41 41 39 39 38 42 37 36 37 36 STEP 3 3x1000W 6x2000W K3 A1 A...

Страница 57: ...V1 0 230V ON OFF Spring back L supply N A1 230V ON OFF Spring back L supply N A2 X23 1 DI9 X23 2 12VDC X23 3 DI10 X23 4 12VDC N2 EX1 V1 0 K5 NC NO COM K7 NC NO COM K6 NC NO COM K8 NC NO COM X35 1 PE X...

Страница 58: ...DO4 NC X11 5 DO4 NO X11 6 DO4 COM X14 1 DI5 12VDC IN GND X14 2 DI5 12VDC OUT TACHO IN X14 3 DI6 12VDC IN GND X14 4 DI6 12VDC OUT TACHO IN X14 5 DI7 12VDC IN GND X14 6 DI7 12VDC OUT TACHO IN X14 7 DI8...

Страница 59: ...X12 5 DO2 NO X12 6 DO2 COM N5 EMRex V4 6 Water cooler circulation pump fail Water cooler 0 10V control Water cooler ret fluid temperature sensor Water cooler power line TV3_P TV3_I TK M M10 Q1 1 2 3...

Страница 60: ...15 2018 06 15 FPP NC NO COM FA NC NO COM Jumper Jumper wired by manufacturer Jumper 24VDC max 50mA 1 2W 24VDC max 50mA 1 2W START STOP CB UC CB UC CB UC X4 1 DI4 X4 2 12VDC N1 MCB V1 0 X22 7 DI8 X22...

Страница 61: ...NC Electrical heater 0 10V control Electrical heater power line L1 1 230V N AHU Controll circuit CB HE 1 X1 1 2 2 1 2 3 1 2 4 1 2 5 1 2 6 1 2 AT1 AT2 RT1 RT2 0 10V GND N 1 2 L1 1 2 N L Electrical hea...

Страница 62: ...2 GND X2 3 AO2 X2 4 GND X2 5 AO3 X2 6 GND X4 1 AI1 X4 2 GND X4 3 AI2 X4 4 GND X4 5 AI3 X4 6 GND X12 1 DO3 NC X12 2 DO3 NO X12 3 DO3 COM X12 4 DO2 NC X12 5 DO2 NO X12 6 DO2 COM N5 EMRex V4 6 Water hea...

Страница 63: ...eater circulation pump fail Water heater 0 10V control Water heater ret fluid temperature sensor Water heater power line TV1 TK M Q1 1 2 3 4 K1 1 2 3 4 K1 A1 A2 230VAC 1 2 01 3 4 01 K1 N L1 PE 0 10 VD...

Страница 64: ...ater automatic protection NC Outdoor air preheater control output 0 10VDC Outdoor air preheater power line control AHU Controll circuit PE Electrical preheater manual protection NC X21 1 DI1 X21 2 12V...

Страница 65: ...5 6 7 7 EI J Balsys EI D Aleksandravi ius Aut T 219 1193 219 1193 0 1 2 PS 7 N C2 02 2018 12 13 2018 12 13 2018 12 13 1 25 PS 2 1 26 2 1 27 2 1 28 2 1 29 2 1 30 2 1 PE R 2 1 N 2 1 L1 2 1 31 2 1 32 2...

Страница 66: ...GND RH 5V TA DTJ Afte rotor air temperature sensor Extraxt air humidity and temperature sensor Control Box AHU Figure 8 1 4 38 7 N C2 The jumpers are installed by the manufacturer see on the automati...

Страница 67: ...r duct system Check the tightness Clean Dampers diffusers grid Check the tightness of connections Clean Switching unit contactor Every 3 to 4 months visually assess the functioning of the switch ing u...

Страница 68: ...reduction LST EN 60204 1 2006 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General re...

Страница 69: ...er the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors...