The stored hot water temperature must not 

exceed 60ºC.
Ensure that the hot supply to the pump is via 

a Salamander approved method. (Figure 3, 6 & 

7).
Jointing compounds (boss white, hemp and 

steel wool) must not be used. Solder fluxes 

must not come into contact with the pump.
The anti-vibration hoses must not be twisted  

or bent.
Higher rated fuses must not be used.

Product Description

Salamander pumps are suitable for pressure boosting vented stored water systems but 

please note that inlet pressures to the pump and water temperatures must not exceed values 

stated in the technical specifications.

Installation instructions

Please follow these installation instructions carefully. Failure to install your pump in 

accordance with these instructions will invalidate your warranty. Any queries should be 

directed to PumpWise on 0191 516 2002 (01844-3212 ROI). 

Do not use Salamander pumps for applications other than those stated within the pump 

description, or connect the pump directly to the cold mains.  

To do so invalidates the warranty.
The plumbing installation must comply with “The Water Supply (Water Fittings) Regulations 

1999”, “BS 6700”, and building regulations.

Salamander pumps should be installed by a competent person and supervision in their use 

should be given to children or anyone with impaired physical or mental capabilities
Please note that:
•  CT Xtra 50, 50+, 54, 75, 75+ & 79 are shower specific pumps.
•  CT FORCE 15 PT, 15 IPT, 20 PT, 20 IPT, 30 PT & 30 IPT, CT Bathroom 60B, 80B, and CT 

Xtra 64H, 69H & 84H are whole house pumps

•  CT FORCE 15 TU, 15 ITU, 20 TU, 20 ITU, 20 SU, 20 ISU, 30 TU, 30 ITU, 30 SU & 30 ISU, 

CT Bathroom, 60BU & 80BU , and CT Xtra 64 HU, 69HU & 84HU  are universal pumps.

•  CT FORCE 20 PS, 20 IPS, 30 PS & 30 IPS, CT Xtra 55, 55+ & 59, 85, 85+, & 89 are positive 

single impellor pumps. 

•  Inlets and outlets must be vertical and plumbed appropriately.

It is essential to ensure that: 

The cold stored water capacity is adequate for the entire 

household requirements (eg minimum 136 litres (30 gal) for shower only, 227 litres (50 gal) 

per bathroom, or 364 litres (80 gal) for one bathroom plus an en-suite shower room).
There is a maximum static head of 10 metres (100kPa/1.0Bar).
Cold supplies to the cylinder and the pump are taken from the opposite side of the cold 

water storage cistern to the cold mains inlet. The bottom of the cold water storage cistern 

must also be checked and cleared of debris (Figure 1).

In systems with more than two bathrooms, 

the cold water supply to the cylinder must  

be in 28mm pipework.
Multiple cold water storage cisterns must 

be linked in accordance with the current  

plumbing regulations with the bottom  

of the cisterns level.
Never put a non-return valve, restricted  

ballofix or an air vent on the supply pipework  

to the pump.

Outlet 

to cylinder

Inlet

Bottom of cold cistern 

must be cleared of debris

Outlet to pump

A Salamander S flange or one 

of the 22mm approved top entry 

flanges (see page 14)

22mm No Stop Essex flange with

76mm dip pipe and birds beak cut

end to limit air being drawn into

the pump

Indirect coil

Pump inlet

Outlet

OR ALTERNATIVELY

Pump at the base of cylinder

MAX

60°C

Cold water storage

Inlet

Min 600mm

Air vents,

both hot

and cold

Outlet

Vent and

other services

No Stop Essex Flange 

MUST be used with 

an anti-gravity loop at 

least 200mm in depth

MAX

60°C

MAX

60°C

Inlet

Outlet

Figure 1: Tank inlet and outlet position

Figure 3: Hot water supply method

Figure 4: Anti-gravity loop - pumps above the hot water cylinder 

The best method is the no 

stop Essex Flange with an 

anti-gravity loop at least 

400mm in depth

Содержание CT FORCE series

Страница 1: ...Pump installation and warranty guide for the CT range of pumps CT FORCE CT Xtra and CT Bathroom ISSUE G JUL 2018 Models shown CT FORCE 15TU CT50 Xtra CT60B...

Страница 2: ...UMPWISE TECHNICAL HELPLINE IMMEDIATELY on 0191 516 2002 01844 3212 ROI DO NOT REMOVE YOUR PUMP FROM THE SYSTEM WITHOUT FIRST RINGING PUMPWISE ON 0191 516 2002 01844 3212 ROI We encourage installers to...

Страница 3: ...nder within 5m of measured pipe 2m MAX of 15mm pipework on inlet connections may be used Allow 100mm on all sides for ventilation Ensure pump is protected from frost If servicing two or more bathrooms...

Страница 4: ...CT FORCE 20 PS 20 IPS 30 PS 30 IPS CT Xtra 55 55 59 85 85 89 are positive single impellor pumps Inlets and outlets must be vertical and plumbed appropriately It is essential to ensure that The cold st...

Страница 5: ...the pump is as close to the hot water cylinder as possible no more than 5m in measured pipework away 5 Mount the pump upright shaft horizontal not screwed down 6 An anti gravity loop AGL of at least...

Страница 6: ...oes to the outlet because either the outlet or the pipework to the outlet are above the height of the base of the cold water cistern Most instances of negative head systems occur in loft conversions o...

Страница 7: ...done during commissioning Step 2 Connecting the pump Use only Salamander supplied AV couplers to connect the pump All associated pipework MUST be thoroughly flushed before making final connections to...

Страница 8: ...valve is positioned above the cold feeds to the cylinder and to the pump aerated water is drawn into the pump as illustrated Chronic aeration of the pump occurs when this problem is combined with ina...

Страница 9: ...ed e g Aga solid fuel appliance or very crudely by the boiler thermostat a Salamander approved HWS TMV must be used Approved flanges cylinders The 22mm No Stop Essex and the other approved top entry f...

Страница 10: ...Fully automatic flow operated requiring 1ltr in 30 sec per side or 2ltr in 30 sec mixed Only applies to positive head pumps Temperature Maximum fluid temperature 60 C Pump noise Salamander has enginee...

Страница 11: ...or notice The CT Xtra and CT Bathroom ranges of pumps are also fully WRAS approved CT Xtra has also been awarded Quiet Mark Part No Description Specification Performance Connection Type Pump Volumetri...

Страница 12: ...Xtra 2 5 Bar Single End Positive Head Shower Pump 3A 170 1 7 200 2 0 220 2 2 21mm 3 86 185 120 160 4 59 293 213 226 Fuse 230 1 50 Regenerative Pressure kPA Bar at 16ltr min Pressure kPA Bar at 8tr mi...

Страница 13: ...w switch sits in lowest position Float sticking in outlet Ensure no debris is in outlet area Flow switch malfunction Contact Technical Advice Line Reduced intermittent flow Incorrect or no anti aerati...

Страница 14: ...ope of the Warranty SALAMANDER PUMPED SHOWER SYSTEMS LTD the Company Warrants subject to the terms and conditions below for the Warranty period s specified in paragraph 3 that the Company shall Repair...

Страница 15: ...is completed online or over the phone within 15 days of purchase Pumps purchased prior to 1st January 2016 come with 2 years warranty iii CT Xtra CT Bathroom UK ROI products manufactured by the Compan...

Страница 16: ...28 29 Notes Notes...

Страница 17: ...er your warranty Apply online at www salamanderpumps co uk Apply by phone 0191 516 2002 Unit 2c Colima Avenue Enterprise Park West Sunderland SR5 3XE Get in touch we re here to help call us on 0191 51...

Отзывы: