16
17
General specifications – CT FORCE
Applications
All Salamander pumps are designed to boost low pressure hot and cold supplies from cistern-
fed services. When supplies from a water heater or a combination boiler are to be boosted
contact the Salamander PumpWise helpline on 0191 516 2002 for guidance.
Voltage
230 volts, 50 Hz.
Motor type
Capacitor start and run induction type motor with stainless steel shaft and in-built resetting
thermal protection (complies with BS5000 part 11).
Maximum head
All Salamander CT FORCE pumps – 10 metres (100kPa/1.0Bar).
Anti-vibration couplers
Do not bend
CT FORCE Pumps are supplied with AV couplers complete with Push Fit connections and
built-in isolating valves. See Technical specifications for details.
Mechanical seals
Rotary mechanical face seals are used. Scale deposits in water supplies can cause the
mechanical seal to stick if left for long periods without use. The pump must be run at least
five minutes every four weeks to ‘exercise’ all working parts.
Connections
¾”
BSP male.
Initiation
Fully automatic, flow operated, requiring 1ltr in 30 sec per side or 2ltr in 30 sec mixed.
Only applies to positive head pumps.
Temperature
Maximum fluid temperature 60ºC.
Pump noise
Salamander has engineered this product range to be as quiet as possible, however no pump
is completely silent. Correct installation (anti-vibration couplers straight, rubber feet fitted)
will minimise noise, vibration and transmission noise.
Standards and approvals
Splash proof rating IPX2; complies with the requirements of
current British and European safety standards for household and
similar electrical appliances; meets with Compliance with European
Community Directives (CE). Due to continuous improvement and
updating specifications may be altered without prior notice.
The CT FORCE range is fully WRAS approved and has been awarded
Quiet Mark.
HWS TMV blending valve controller
A Salamander approved HWS Blending valve controller will protect booster pumps in systems
where the temperature of the stored hot water is uncontrolled – see below.
Usable capacity
minimum 50 galls
per bathroom
Vent
and other
services
Salamander approved HWS TMV Blending
valve controller is factory set at 55 - 60°C
MAX
60°C
Figure 16: HWS blending valve controller to pump
Содержание CT FORCE series
Страница 16: ...28 29 Notes Notes...