General  

specifications

Applications

The HomeBoost

 pump is designed to boost 

low mains water pressure into a domestic 
house to improve low water flow from the 
mains supply at peak demand times. It can be 
used in two distinct applications:
1.   Boosting the incoming mains water supply 

to a whole house

2.   Boosting the inlet mains water supply 

solely to a combination (combi) boiler.

HomeBoost

 will increase the low incoming 

water flow up to 12 l/min which complies with 
the Water Supply (Water Fittings) Regulations 
1999. As the incoming flow varies, the 
HomeBoost

 will adapt to maintain 12 l/min, 

and will move into idle if sufficient flow is 
received from the water main.

Power supply

230 volts, 50Hz, 1.8A, continuously rated.

Pump noise

With the technical advances achieved in 
the HomeBoost

 pump, Salamander has 

taken another step forward in supplying all 
our customers with even quieter centrifugal 
pumps. However, no pump is completely 
silent and this type of pump is characterised 
by a high pitched hum or whine.

Mechanical seals

Scale deposits in water supplies can cause the 
mechanical seal to stick if left for long periods 
without use. We recommend that the pump 
be run for at least five minutes every four 
weeks to ‘exercise’ all the working parts.

Connections

¾” BSP male.

Fittings

1 off isolating ball valve with ¾” female tap 
connector x 22mm compression

1 off ¾” female tap connector x 22mm 
compression
2 off 22mm x 15mm compression reducer sets

Initiation

Fully automatic, water flow operated, requiring 
3 litres per minute flow rate to initiate.

Temperature

Maximum fluid temperature is UK cold water 
mains temperature (max 20°C).

Standards and approvals

•   WRAS approved product
•   Complies with the Water Supply  

(Water Fittings) Regulations 1999

•  Splash proof rating IPX4
•   Complies with European Community 

Directives (CE)

•   Tested for sound power level in  

accordance with methods set out in  
BS EN ISO 3744:2010 and BS EN ISO 
20361:2009, and results calculated to  
BS EN ISO 11203: 2009

•   EN 55014-1:2006 Electromechanical 

compatibility (EMC) – Requirements 
household appliances, electrical goods and 
similar apparatus (Part 1)

•   EN 60335-1:2002 and EN 60335-2-41:2003 

Household and similar electrical appliances – 
safety (Part 1 General requirements and Part 
2-41 Particular requirements for pumps).

The company operates a policy of continuous 
development and reserves the right to change 
any of the specifications of its products  
without prior notice. All information data  
and illustrations given in this leaflet may be 
subject to variation.

Safety in operation

These appliances are not intended for use 
by persons (including children) with reduced 
physical, sensory or mental capabilities, or lack 
of experience and knowledge, unless they have 
been given supervision or instruction concerning 
use of the appliance by a person responsible for 
their safety. Children should be supervised to 
ensure that they do not play with the appliance.

x142741_SP_p2_lh.indd   9

16/12/2014   15:11

Содержание HomeBoost

Страница 1: ...ISSUE 3 January 2015 Pump installation and warranty guide for HomeBoost Patented Product x142741_SP_p5_vw indd 1 09 01 2015 12 43...

Страница 2: ...fitting will invalidate the warranty If your installation is complicated or you have any questions please consult the PumpWise Technical Helpline immediately 0191 516 2002 Additional help can also be...

Страница 3: ...lication notes 4 5 Typical installations 6 Commissioning 7 General specifications 8 Lighting codes Trouble shooting 9 Fittings Kit 10 PumpWise and warranty 11 To the installer 12 Terms and conditions...

Страница 4: ...ets are between the stop tap and your HomeBoost they must be fitted with a non return valve NRV Do s Install vertically or horizontally mounted on cold water mains inlet to the combi boiler Locate the...

Страница 5: ...estricted incoming pipework and replacement water pipes should be installed in this scenario Installation must comply with the relevant requirements or local byelaws It is recommended that HomeBoost i...

Страница 6: ...polymer pump body 6 Electrical requirements The HomeBoost must be connected to the electrical supply using the mains cable with the attached plug This plug must be connected to an accessible socket t...

Страница 7: ...ll valve Tap connector Tap connector Isolating Ball valve Isolation valve for combi boiler Figure 4 Modified pipe work for clearance Mains stop tap Pipe centre to wall 37mm Figure 6 Earth continuity 4...

Страница 8: ...t pump pipe work 2 Check that all isolating valves are open 3 Turn mains water on at the stop tap 4 Ensure all air is purged from the system 5 Check for natural flow on the cold outlets or hot outlets...

Страница 9: ...ector x 22mm compression 2 off 22mm x 15mm compression reducer sets Initiation Fully automatic water flow operated requiring 3 litres per minute flow rate to initiate Temperature Maximum fluid tempera...

Страница 10: ...ater supply only for several minutes Pump starts with all outlets closed Leak in system Check for leaks Outlet open Ensure all outlets are fully closed or capped i e no dead legs in pipe work Pump is...

Страница 11: ...compression 2 x reducer 22mm x 15mm compression reducer Fitting Instructions WHOLE HOUSE COMBI ONLY WHOLE HOUSE COMBI ONLY Isolating ball valve Tap connector Isolating ball valve Tap connector Flat w...

Страница 12: ...Our PumpWise commitment Our PumpWise helpline is here to help you and we aim to provide a support service second to none Installers and consumers can be sure of a speedy response to requests for tech...

Страница 13: ...ty shall only be enforceable by you if the following terms and conditions have been complied with a That the pump has been installed in accordance with the installation instructions guidance and advic...

Страница 14: ...13 Notes x142741_SP_p2_lh indd 14 16 12 2014 15 11...

Страница 15: ...x142741_SP_p2_lh indd 15 16 12 2014 15 11...

Страница 16: ...Salamander Pumped Shower Systems Limited Unit 2c Colima Avenue Sunderland SR5 3XE Tel 0191 516 2002 Fax 0191 548 4445 Email service salamanderpumps co uk x142741_SP_p2_lh indd 16 16 12 2014 15 11...

Отзывы: