Power On/Off

Button

Power on

Before turning on the power switch, the main battery switch
must be closed. Touch the power switch, and all the indicators
will self-check and light. (if the gird power or PV has been
connected in advance, the power will automatically turn on).

Reset

In emergency case, the system can not work normally, can press
the power button for more than 10 seconds, the system will
enter to the reset status, all the indicators will self-check and
light up again.

Reset to factory setting

If the settings are out of order in APP and need reset to factory
settings, you can press the button for 8 times continuously, the
system will enter the factory restoration mode and restore the
system default parameters.

Power On/Off

Press the button for 10S

the indicator will flash and the system

will be power off. When power off the system, should meet the
following 3 conditions, otherwise can not be powered off:
Condition 1: No Solar
Condition 2: No Grid power
Condition 3: The work mode switch is in standby mode.

7

On grid indicator

1.When it is on grid mode and feeds power to grid, the indicator keeps light.
2.When it is on grid mode and in standby status

it flashes every 3 seconds.

3.When it is on grid mode and AC keeps charging,it flashes every 0.5 second.

8

Off grid indicator

The system works in off-grid mode, and the battery is discharging with load.

9

Solar charge

indicator

1.In fast charge, it flashes every 0.5 second.
2.It will keep light in float charge.
3.It will not light when no solar charge.

10

Error code

indicator

It will be lighted in low battery voltage, over temperature, overload protection or other
damage.

11

WIFI

WIFI Antenna installation port

12.13

AC output Port

The 2 sockets have power only in off grid mode

14

SOC

1.Light in red color 0-25%
2.Light in blue color 26-50%
3.Light in green color 51-75%
4.Light in white color 76-100%

8. WiFi Setting

No.

Item

Setting format for

reference

Explanation

1

PCS Switch

1

Turn on(Default)

2

Standby

When the system is in on-grid or off-grid work model,if
select as “Standby”state, the system will be in standby
state and need reset the work model as “Turn On” state
before the system re-start work

2

1

ST

Start charging

Time

00

00

Setting between 0-23 hour and 0-59 minute. For example,
set as 07:30, it means that the 1

st

charge period will start

at 7:30

Содержание ESS-1KW

Страница 1: ...User Manual ESS 1KW Energy Storage System WIFI APP download page ftp smartree y66 dnsnd com WIFImonitor apk...

Страница 2: ...face 1 4 Product Features 1 5 Warranty Policy 2 6 Basic System Structure 2 7 Installation 3 7 8 WIFI Setting 7 10 9 System Wire Connection 11 13 10 Switching Operation Steps 13 14 11 Solar Panel Selec...

Страница 3: ...6 Be very cautious when working with metal tools on or around the energy storage system Dropping a tool may cause a spark or short circuit in batteries or other electrical parts even cause an explosio...

Страница 4: ...nsportation or other external force intrusion The transportation methods should be properly selected by the user and the seller just assist to send them to the shipment agent 4 Under the following cir...

Страница 5: ...onfirm the following points before installation Do not install the energy storage system on the flammable materials device Install the system on the solid surface to prevent falling off Install the en...

Страница 6: ...ts of expansion screws M6 60mm and 3 sets of screws KM5 10mm The screws must be fixed tightly to avoid falling off and hurt others Step 2 Place the energy storage system to hanging bracket Attention W...

Страница 7: ...nection ports 1 AC input over current reset breaker 2 AC input port 3 Reserve lithium battery balancing port If the internal lithium battery cells get unbalanced after years use they can be balanced v...

Страница 8: ...harging 3 The grid power grid is normal and in the input range 4 Work mode switch is selected to the grid connected mode Timing grid connection mode can be set via APP can set the start time of grid c...

Страница 9: ...mode and feeds power to grid the indicator keeps light 2 When it is on grid mode and in standby status it flashes every 3 seconds 3 When it is on grid mode and AC keeps charging it flashes every 0 5...

Страница 10: ...Set between 1 40A For example 20 0 means the charge current of 1st charging period is 20A This charging here refers to the mains charging instead of solar charging For solar charger it will be automat...

Страница 11: ...harge period The SOC will be compared with the discharge time whichever arrives first and it stops first For example SOC is set as 50 while the discharging feeding to grid time is set as 10 minutes Wh...

Страница 12: ...nd discharge period 20 0 Set between 1 20A For example 20 0 means the charge current of 2nd discharging period to grid is 20A This discharging here refers to battery power feeds to grid For example if...

Страница 13: ...f solar panel with energy storage system Caution Do not reverse connect the positive and negative poles of solar panel Be careful of electric shock 9 2 1 Place all connection wires at the back side of...

Страница 14: ...ed in the package to the AC input port of energy system Make sure all wires are fixed properly and tightly to avoid heating caused by loose or poor contact 9 3 3 Place all connection wires at the back...

Страница 15: ...nna to the energy storage system 10 Switching Operation Steps 10 1 Double check if all wires are connected correctly and tightly 10 2 After double confirmation turn on the battery breaker 10 3 Press t...

Страница 16: ...he grid power fails or is abnormal it needs work as off grid mode can connect small household loads to the AC output socket running in off grid mode 10 8 Turning off steps are reversed 11 Solar panel...

Страница 17: ...ed in somewhere with high temperature and poor ventilation Lithium Battery Protection The LiFePO4 cell is over voltage protection The internal cell is over charged Just disconnect charging and dischar...

Страница 18: ...les 25 1500cycles 45 Grid input Parameters 1 Max Power Feed to Grid 600W Max 2 AC Input Current 0 40A Adjustable 3 AC Input Range 90 265VAC 4 AC Input Frequency Range 50HZ 3HZ 5 THDI 3 6 Rectification...

Страница 19: ...grid mode grid tied mode and other functions Protection Functions 7 1 IP Level IP21 7 2 Protection Overcharge protection Over discharge protection Over current protection Short circuit protection Ove...

Отзывы: