6
7.4.2 Side connection ports
The detail introduction to the button, LED indicator and ports as follows:
Code
No.
Name
Function
Function description in details
5
Work mode switch
On Grid Mode
Smart grid-connected mode (default setting) : 4 conditions must
be met before the smart grid-connected mode is entered.
Grid-connected power is adjusted in real time according to the
solar power generation.
1: The SOC of the battery is more than 90%
2: Solar is charging
3: The grid power grid is normal and in the input range
4: Work mode switch is selected to the grid-connected mode
Timing grid-connection mode (can be set via APP) : can set the
start time of grid-connection, grid-connection working time,
grid-connection current, SOC value.
Standby Mode
In this mode, can not work in off grid mode or on grid mode, but
the battery will continue to be charged if there is solar energy.
Off Grid Mode
In this mode, the system works in off-grid mode, and the AC
output port have AC power and can power some small AC loads,
such as TV sets, fans, LED lights and computers. If there is solar,