4-203
Fault Diagnosis of Electric System (Mode E)
7
8
YES
NO
6
YES
NO
YES
NO
• 10
〜
14V
• Turn starter switch
to START.
• 10
〜
14V
• Turn starter switch
to START.
Is stated voltage
present at interlock
relay terminal that
carries wire W?
Is stated voltage
present at interlock
relay coil that
carries wire GY?
Is stated voltage
present at starter
switch terminal C
that arries wire W?
Starter faulty.
Renew.
Renew.
Renew.
Renew.
Wire from interlock relay
terminal to starter terminal S
not connected or incorrectly
connected.
Repair or renew
wire.
Repair or renew
wire.
Repair or renew
wire.
Repair or renew
wire.
Charge or
renew battery.
Interlock relay faulty.
F-R lever interlock switch
faulty.
Wire W from starter switch
terminal C to interlock relay
termianl not connected or
incorrectly connected.
(including fuse)
Starter switch faulty.
(between B and C)
Cable from battery relay
terminal NO to starter not
connected or incorrectly
connected.
Battery relay contact faulty.
Battery capacity lowered.
Battery relay coil faulty.
Wire LgR or LgW from starter
switch terminal BR to battery
relay terminal BR not connected
or incorrectly connected.
To A on next page
Renew.
Renew.
Possible cause
Remedy
• 10
〜
14V
Содержание SW352
Страница 4: ......
Страница 5: ...SPECIFICATIONS ...
Страница 6: ......
Страница 12: ...MEMO ...
Страница 13: ...STRUCTURE AND OPERATION ...
Страница 14: ......
Страница 77: ...INSPECTION AND ADJUSTMENT ...
Страница 78: ......
Страница 91: ...FAULT DIAGNOSIS ...
Страница 92: ......
Страница 116: ...MEMO ...
Страница 127: ...DISASSEMBLY AND ASSEMBLY ...
Страница 128: ......
Страница 132: ...MEMO ...