9-095
TROUBLESHOOTING
3-3-4. Vibrator does not stop
Check point
Cause
Check/Action
1. Servo Control
Valve
Servo control valve spool does not return to
neutral position.
Measure vibrator high/low circuit pressure.
If not equal, check and adjust servo control
valve or replace it if necessary.
•
•
2. Vibrator Pump
Vibrator pump swash place does not return
to neutral position.
Repair vibrator pump or replace it if
necessary.
3-3-5. Vibrator system is overheating
Check point
Cause
Check/Action
1. Oil Level of
Hydraulic Oil Tank
Oil level in hydraulic oil tank is low.
Fill tank until correct oil level is obtained.
2. Oil Cooler
Cooling efficiency is reduced due to clogged
oil cooler fins.
Clean oil cooler fins.
3. Vibrator Circuit
Pressure
If circuit pressure setting is excessively low,
relief valve opens, causing temperature of
hydraulic oil in circuit to rise.
Measure vibrator circuit pressure.
If low, check and clean relief valve or
replace it if necessary.
•
•
If load is excessively heavy, relief valve
opens, causing temperature of hydraulic oil
in circuit to rise.
Measure vibrator circuit pressure.
If high, decrease vibration load.
•
•
4. Suction Filter for
Steering • Charge
Pump
Load of steering • charge pump increases
due to clogged filter, causing temperature of
hydraulic oil in circuit to rise.
Clean suction filter or replace it if necessary.
5. Hydraulic Oil Filter 1 Charge circuit pressure increases due to
clogged filter.
Clean hydraulic oil filter 1 or replace it if
necessary.
3-3-6. Abnormal noise from vibrator system
Check point
Cause
Check/Action
1. Vibrator Bearings
Vibrator bearings supporting eccentric shaft
are damaged.
Replace vibrator bearings.
2. Hydraulic Hose
Clamp
Vibrator sound of hydraulic hose is
generated because clamp securing
hydraulic hose is loose.
Tighten bolts of loose hydraulic hose clamp
to specified torque.
3. Suction Filter for
Steering • Charge
Pump
Cavitation is occurring in steering • charge
pump due to clogged filter.
Clean suction filter or replace it if necessary.
4. Vibrator Motor
Internal bearing of vibrator motor is
damaged.
Repair vibrator motor or replace it if
necessary.
Содержание SV540 Series
Страница 1: ...SV540 SHOP MANUAL 3498 6418A 0 ...
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 13: ...SAFETY ...
Страница 14: ......
Страница 22: ......
Страница 23: ...SPECIFICATIONS ...
Страница 24: ......
Страница 25: ......
Страница 42: ......
Страница 43: ...ENGINE AND CONTROLS ...
Страница 44: ......
Страница 46: ......
Страница 48: ......
Страница 53: ...HYDRAULIC SYSTEMS ...
Страница 54: ......
Страница 55: ......
Страница 58: ......
Страница 60: ......
Страница 62: ......
Страница 64: ......
Страница 66: ......
Страница 67: ......
Страница 74: ......
Страница 76: ......
Страница 78: ......
Страница 80: ......
Страница 84: ......
Страница 85: ...ELECTRICAL SYSTEM ...
Страница 86: ......
Страница 90: ......
Страница 92: ......
Страница 94: ......
Страница 108: ......
Страница 118: ......
Страница 119: ...VIBRATORY DRUM REAR AXLE ...
Страница 120: ......
Страница 128: ......
Страница 158: ......
Страница 160: ......
Страница 162: ......
Страница 169: ...BRAKE ...
Страница 170: ......
Страница 172: ......
Страница 174: ......
Страница 178: ......
Страница 179: ...INSPECTION AND ADJUSTMENT ...
Страница 180: ......
Страница 206: ......
Страница 207: ...TROUBLESHOOTING ...
Страница 208: ......