TROUBLESHOOTING
2-6. Vibration
Check following items before troubleshooting.
No blown fuses and power is applied up to fuses.
When measuring voltage and current without disconnecting connectors, refer to
“Measuring voltage and current
flowing using tester” (P.9-006 to P.9-008)
.
Check any ground circuit which belongs to components to be checked.
Engine check lamp must not be lighting. If engine check lamp lights, refer to “Service information” of engine
manufacturer.
Throttle switch to “MID” or “FULL”.
2-6-1. No vibration occurs 1/3
Vibration mode change switch must be “CONT” (continuous mode).
Vibration select switch must not be “
”.
Check whether ECO controller red LED shows any blink.
1) when red LED shows no blink.
Reference Fig.: 2-6-1
Check point
Check/Cause
Action
1. Vibrator Proportional
Solenoid 1
Disconnect harness and measure resistance of coil.
Standard resistance : 36 Ω
If resistance is abnormal, vibrator proportional solenoid 1
is faulty.
•
•
Replace vibrator
proportional solenoid 1.
2. Vibrator Proportional
Solenoid 2
Disconnect harness and measure resistance of coil.
Standard resistance : 36 Ω
If resistance is abnormal, vibrator proportional solenoid 2
is faulty.
•
•
Replace vibrator
proportional solenoid 2.
3. Vibration Select Switch
(1) when starter switch is ON, measure voltage between
vibration select switch terminal 1 inlet wire Y, terminal 4
inlet wire Y and chassis ground.
Standard voltage : 24 V or more
(2) when starter switch is ON and vibration select switch is
“
”, measure voltage between vibration select
switch terminal 2 outlet wire YR and chassis ground.
Standard voltage : 24 V or more
(3) when starter switch is ON and vibration select switch is
“
”, measure voltage between vibration select
switch terminal 5 outlet wire YB and chassis ground.
Standard voltage : 24 V or more
If above item (1) is OK and item (2) or (3) is NG, vibration
select switch is faulty.
•
Replace vibration select
switch.
4. Vibration Mode Change
Switch
(1) when starter switch is ON, measure voltage between
vibration mode change switch terminal 1 inlet wire RL
and chassis ground.
Standard voltage : 24 V or more
(2) when starter switch is ON, measure voltage between
vibration mode change switch terminal 2 outlet wire Y
and chassis ground.
Standard voltage : 24 V or more
If above item (1) is OK and item (2) is NG, vibration mode
change switch is faulty.
•
Replace vibration mode
change switch.
•
•
•
•
•
•
•
•
Содержание SV540 Series
Страница 1: ...SV540 SHOP MANUAL 3498 6418A 0 ...
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 13: ...SAFETY ...
Страница 14: ......
Страница 22: ......
Страница 23: ...SPECIFICATIONS ...
Страница 24: ......
Страница 25: ......
Страница 42: ......
Страница 43: ...ENGINE AND CONTROLS ...
Страница 44: ......
Страница 46: ......
Страница 48: ......
Страница 53: ...HYDRAULIC SYSTEMS ...
Страница 54: ......
Страница 55: ......
Страница 58: ......
Страница 60: ......
Страница 62: ......
Страница 64: ......
Страница 66: ......
Страница 67: ......
Страница 74: ......
Страница 76: ......
Страница 78: ......
Страница 80: ......
Страница 84: ......
Страница 85: ...ELECTRICAL SYSTEM ...
Страница 86: ......
Страница 90: ......
Страница 92: ......
Страница 94: ......
Страница 108: ......
Страница 118: ......
Страница 119: ...VIBRATORY DRUM REAR AXLE ...
Страница 120: ......
Страница 128: ......
Страница 158: ......
Страница 160: ......
Страница 162: ......
Страница 169: ...BRAKE ...
Страница 170: ......
Страница 172: ......
Страница 174: ......
Страница 178: ......
Страница 179: ...INSPECTION AND ADJUSTMENT ...
Страница 180: ......
Страница 206: ......
Страница 207: ...TROUBLESHOOTING ...
Страница 208: ......