10-007
TROUBLESHOOTING
GW750‑2‑10002
Measurement on a lead cable
Connector
Wire
Test probe
Needle
Lead cable
Equipment B
Test harness
Equipment A
1
2 3
Measurement using a test harness
Measurement from the backside of connector
Measurement method
For measurement of voltage, connect the tester probes in parallel to the portion to be measured. Because
the voltage can be measured only when the connector is connected in position, contact the tester probes to
the terminals without disconnecting the connector. The following methods are available:
①
Measurement using a test harness
• Prepare the test harness for the measurement.
②
Measurement from the backside of connector
• Insert a wire from the backside of the connector.
③
Measurement on a lead cable
• Remove the bundling tape from the harness to separate each cable, and stick the needle into the
relevant cable.
(NOTICE)
• Except for preparing the test harness, proper protection must be made after the measurement to
prevent corrosion in the connector terminals or harnesses.
Содержание R2H-2
Страница 1: ...R2H 2 SHOP MANUAL 3498 66344 0 ...
Страница 8: ...SAFETY ...
Страница 16: ...SPECIFICATIONS ...
Страница 23: ...ENGINE AND CONTROLS ...
Страница 30: ...HYDRAULIC SYSTEMS ...
Страница 47: ...ELECTRICAL SYSTEM ...
Страница 53: ...DRUM ...
Страница 58: ...BRAKE ...
Страница 61: ...WATER SPRAY SYSTEM ...
Страница 63: ...INSPECTION AND ADJUSTMENT ...
Страница 79: ...TROUBLESHOOTING ...