10-044
TROUBLESHOOTING
2-5-6. Backup lamp does not light
Reference Fig.: 2-5-1
Check point
Check/Cause
Action
1. Each Bulb
• Check that none of lamp bulbs is burned out or has a
contact failure.
• Bulb is faulty or poorly connected.
Replace each bulb.
2. Backup buzzer Switch (1) When starter switch is ON, measure voltage between
backup buzzer switch COM terminal inlet wire YL and
chassis ground.
Standard voltage: 12 V or more
(2) When starter switch is ON and F-R lever is in reverse,
measure voltage between backup buzzer switch NO
terminal outlet wire RY and chassis ground.
Standard voltage: 12 V or more
• If above (1) is OK and (2) is NG, backup buzzer switch is
faulty.
Replace backup buzzer
switch.
3. Harness Connecting
Between Terminals
Measure resistance of harness connecting between
terminals.
Standard resistance: 10 Ω or less
• If resistance is abnormal, harness is faulty.
Repair or replace
harness.
2-5-7. Stop lamp does not light
Reference Fig.: 2-5-1
Check point
Check/Cause
Action
1. Each Bulb
• Check that none of lamp bulbs is burned out or has a
contact failure.
• Bulb is faulty or poorly connected.
Replace each bulb.
2. Foot Brake Switch
(1) When starter switch is ON, measure voltage between
foot brake switch terminal inlet wire WB and chassis
ground.
Standard voltage: 12 V or more
(2) When starter switch is ON while foot brake is
depressed, measure voltage between foot brake
switch terminal outlet wire LgB and chassis ground.
There is no electricity in normal condition.
• If above (1) is OK and (2) is NG, foot brake switch is
faulty.
Replace foot brake
switch.
3. Stop Lamp Relay
(1) When starter switch is ON, measure voltage between
stop lamp relay terminal c inlet wire WB and chassis
ground.
Standard voltage: 12 V or more
(2) When starter switch is ON, measure voltage between
stop lamp relay terminal f outlet wire GY and chassis
ground.
There is no electricity in normal condition.
(3) When starter switch is ON while foot brake is
depressed, measure voltage between stop lamp relay
terminal f outlet wire GY and chassis ground.
Standard voltage: 12 V or more
• If above item (1) adn (2) are OK and item (3) is NG, stop
lamp relay is faulty.
Replace stop lamp relay.
4. Harness Connecting
Between Terminals
Measure resistance of harness connecting between
terminals.
Standard resistance: 10 Ω or less
• If resistance is abnormal, harness is faulty.
Repair or replace
harness.
Содержание R2H-2
Страница 1: ...R2H 2 SHOP MANUAL 3498 66344 0 ...
Страница 8: ...SAFETY ...
Страница 16: ...SPECIFICATIONS ...
Страница 23: ...ENGINE AND CONTROLS ...
Страница 30: ...HYDRAULIC SYSTEMS ...
Страница 47: ...ELECTRICAL SYSTEM ...
Страница 53: ...DRUM ...
Страница 58: ...BRAKE ...
Страница 61: ...WATER SPRAY SYSTEM ...
Страница 63: ...INSPECTION AND ADJUSTMENT ...
Страница 79: ...TROUBLESHOOTING ...