10-058
TROUBLESHOOTING
2-5-18. Flood lamp indicator lamp does not light
• Check that flood lamp lights.
Reference Fig. : 2-5-3
Check point
Check/Cause
Action
1. Harness
• Measure resistance between flood lamp relay terminal 5
wire RG and combination meter connector terminal wire
No. 38 wire RG.
Standard resistance : 10 Ω or less
• If resistance is abnormal, harness is faulty.
Repair or replace
harness.
2. Combination Meter
(Flood lamp indicator)
(1) When starter switch is ON, measure voltage between
combination meter terminal wires and ground terminal
wire.
• Battery terminal wire No. 57 inlet wire L and ground
terminal wire No.2 wire B
• Starter switch terminal wire No. 37 inlet wire WY and
ground terminal wire No.2 wire B
Standard voltage : 12 V or more
(2) When starter switch is ON and flood lamp switch is
ON, measure voltage between combination meter flood
lamp indicator lamp terminal wire No.38 inlet wire RG
and chassis ground.
Standard voltage : 12 V or more
• If above items (1) and (2) are OK and flood lamp indicator
lamp does not light, combination meter is faulty.
Replace combination
meter.
2-5-19. Side marker lamp indicator lamp does not light
• Check that head lamp, side marker lamp, tail lamp and license lamp light.
Reference Fig.: 2-5-3
Check point
Check/Cause
Action
1. Harness
• Measure resistance between lighting switch terminal 3
wire RL and combination meter connector terminal wire
No.45 wire RL.
Standard resistance value: 10 Ω or lower.
• If above resistance value is abnormal, harness is faulty.
Repair or replace
harness.
2. Combination Meter
(Side marker lamp
indicator)
(1) When starter switch is ON, measure voltage between
combination meter terminal wires and ground terminal
wire.
• Battery terminal wire No. 57 inlet wire L and ground
wire No.2 wire B
• Starter switch terminal wire No. 37 inlet wire WY and
ground wire No.2 wire B
Standard voltage: 12 V or more
(2) When starter switch is ON and lighting switch is “
”,
measure voltage between combination meter side
marker lamp indicator lamp terminal wire No. 45 inlet
wire RL and chassis ground.
Standard voltage: 12 V or more
• If above (1) and (2) are OK and side marker lamp
indicator lamp does not turn on, combination meter is
faulty.
Replace combination
meter.
Содержание R2H-2
Страница 1: ...R2H 2 SHOP MANUAL 3498 66344 0 ...
Страница 8: ...SAFETY ...
Страница 16: ...SPECIFICATIONS ...
Страница 23: ...ENGINE AND CONTROLS ...
Страница 30: ...HYDRAULIC SYSTEMS ...
Страница 47: ...ELECTRICAL SYSTEM ...
Страница 53: ...DRUM ...
Страница 58: ...BRAKE ...
Страница 61: ...WATER SPRAY SYSTEM ...
Страница 63: ...INSPECTION AND ADJUSTMENT ...
Страница 79: ...TROUBLESHOOTING ...