10-040
TROUBLESHOOTING
2-5-4. Turn signal light does not blink
Reference Fig.: 2-5-1
Check point
Check/Cause
Action
1. Each Bulb
• Check that none of lamp bulbs is burned out or has a
contact failure.
• Bulb is faulty or poorly connected.
Replace each bulb.
2. Flasher Unit
(1) When starter switch is ON, measure voltage between
flasher unit terminal B inlet wire Gy and chassis
ground.
Standard voltage: 12 V or more
(2) When starter switch is ON and turn signal lever is
moved, measure voltage between flasher unit terminal
L outlet wire GY and chassis ground.
Standard voltage: 12 V or more with constant
intervals
• If above (1) is OK and (2) is NG, flasher unit is faulty.
Replace flasher unit.
3. Turn Signal Switch
(1) When starter switch is ON and turn signal lever is
moved, measure voltage between turn signal switch
terminal inlet wire GY and chassis ground.
Standard voltage: 12 V or more with constant
intervals
(2) When starter switch is ON and turn signal lever is
moved, measure voltage between turn signal switch
terminal wires and chassis ground.
Front and rear turn signal lamp (R): Outlet wire GB
Front and rear turn signal lamp (L) : Outlet wire GR
Standard voltage: 12 V or more with constant
intervals
• If above (1) is OK and (2) is NG, turn signal switch is
faulty.
Replace turn signal
switch.
4. Harness Connecting
Between Terminals
Measure resistance of harness connecting between
terminals.
Standard resistance: 10 Ω or less
• If resistance is abnormal, harness is faulty.
Repair or replace
harness.
Содержание R2H-2
Страница 1: ...R2H 2 SHOP MANUAL 3498 66344 0 ...
Страница 8: ...SAFETY ...
Страница 16: ...SPECIFICATIONS ...
Страница 23: ...ENGINE AND CONTROLS ...
Страница 30: ...HYDRAULIC SYSTEMS ...
Страница 47: ...ELECTRICAL SYSTEM ...
Страница 53: ...DRUM ...
Страница 58: ...BRAKE ...
Страница 61: ...WATER SPRAY SYSTEM ...
Страница 63: ...INSPECTION AND ADJUSTMENT ...
Страница 79: ...TROUBLESHOOTING ...