VM600
- 6 -
Chapter 1 Product information
1.1
Technical specifications
Item
Specifications
Control
features
Control mode
V/F control
Startup torque
0.5Hz/100%
Speed range
1
:
50
Speed stability accuracy
±1%
Carrier frequency
1kHz
~
6kHz
;
Overload capacity
60s for 150% of the rated current, 1s for 180% of the rated
current.
Torque boost
0.0%
~
30.0%
Input and
Output
Input voltage range
220V/380V; fluctuation range :±15%
Input frequency range
50/60Hz
;
fluctuation range :±5%
Output voltage range
0-input voltage; the error is less than 5%
Output frequency range
0-400Hz
Basic
function
Running command source
Three command source
:
keypad; control terminals; serial
communication port.
Frequency source
such as digital setting, analog voltage setting, analog current
setting, serial communication port setting.
DC braking
Braking time: 0.0s
~
50.0s;
Braking action current value: 0.0%
~
100.0%
Simple PLC/Multiple
speeds
It implements up to 8 speeds via the simple PLC function or
combination of DI terminal states.
Protection mode
Motor short-circuit detection at power-on, input/output phase
loss protection, overcurrent protection, overvoltage protection,
undervoltage protection, overheat protection, overload
protection and so on.
Display
and Key
operation
LED display
It displays the parameters.
Parameters locking
function
It can lock the parameters to prevent malfunction.
Environ
ment
Installation location
Indoor, free from direct sunlight, dust, corrosive gas,
combustible gas, oil smoke, vapour, drip or salt.
Altitude
Lower than 1000m. When it is higher than 1000m, for every