VM600
- 14 -
Parameter
Name
Setting Range
Default
Property
Address
F0.13
Retentive of digital setting
frequency
0
:
No retentive
1
:
retentive
1
●
000D
F0.14
Fan operating mode
0
:
Run when motor is running
1
:
Keep run when power on
0
○
000E
F0.15
AI1 Input Option
0
:
0-10V
1
:
4-20mA
2: 0-20mA
3
:
0-5V
4
:
0.5-4.5V
0
○
000F
F1.00
Default Setting Restoring
0
:
No Operation
1
:
Restore to factory default setting (not
including F2 parameters)
2
:
Clear error records
0
●
0100
F1.01
Parameters Lockup
0
:
Invalid
1
:
Valid
0
○
0101
F1.02
User Password
0
~
65000
0
○
0102
F2.00
Motor Rated Power
0.1kW
~
2.2kW
Determined
by
Drive
Model
●
0200
F2.01
Motor Rated Voltage
0-380V
Determined
by
Drive
Model
●
0201
F2.02
Motor Rated Frequency
0- F0.05
Determined
by
Drive
Model
定
●
0202
F2.03
Motor Rated Current
1.00-10.00
Determined
by
Drive
Model
●
0203
F2.05
Type of Motor
0
:
Single Phase
1
:
Three Phase
0
●
0205
F2.06
Single-phase motor main
and auxiliary winding turns
ratio
10
~
200
80
○
0206
F2.07
Single-phase motor current
correction factor
50
~
200
130
○
0207
F3.00
V/F Curve Setting
0
:
Linear
1
:
Multi-Point
0
●
0300
F3.01
Multi-Point Frequency 1
0.00Hz~F3.03
3
●
0301
F3.02
Multi-Point Voltage 1
0.0%~100.0%
8
●
0302
F3.03
Multi-Point Frequency 2
F3.03~F3.05
5
●
0303
F3.04
Multi-Point Voltage 2
0.0%~100.0%
15
●
0304