- 39 -
short circuit caused by wrong operation during battery wiring.
To parallel B1 to the AS1, please follow the procedures below:
Step 1:
Please remove battery cover plate of the AS1 device from
the lower right area and right side of the B1 unit before wiring. (The
cable connected to the Battery Switch inside the cover plate can be
plugged out first if needed).
Fig. 4.6 Removing the cover plate from AS1 and B1
Step 2:
Lead power lines through the waterproof nut of the AS1 and
B1 respectively, make sure the lines are connected correctly (BAT+
of AS1 to BAT+ of B1, BAT- of AS1 to BAT- of B1 and LINK of AS1 to
LINK of B1).
Remove this cover plate
from AS1
Remove this cover plate
from Secondary