54
Measurement
Range
Accuracy
Resolution
Indoor
Temperature
0 to 60 °C
± 1 °C
0.1 °C
Outdoor
Temperature
-40 to 60 °C
± 1 °C
0.1 °C
Indoor
Humidity
10 to 99 %
± 5% (only guaranteed
between 20 to 90%)
1 %
Outdoor
Humidity
10 to 99%
± 5% (only guaranteed
between 20 to 90%)
1 %
Sensors 1-8
Temperature
-40 to 60 °C
± 1 °C
0.1 °C
Sensors 1-8
Humidity
10 to 99%
± 5% (only guaranteed
between 20 to 90%)
1 %
UV Index
1 to 15+
± 1
± 1
Sunlight
0 to 200klux
± 15%
± 15%
Rain
0 to 9999mm <15mm
:
±1 mm,
15mm to 9999mm
:
±7%
<1000mm (0.3mm)
>1000mm (1mm)
Wind Direction 0 - 360 º
± 10º (16 point
compass)
± 1º (16 point
compass)
Wind Speed
0 to 50 m/s
2 m/s ~10 m/s
:
±3m/s,
10m/s ~50 m/s
:
±10%
(whichever is greater)
0.1 m/s
Barometric
Pressure:
300 to 1100
hpa
± 3 hpa
0.1 hpa