Prohibition of
modification.
Use specified
parts.
Do not bring
a child close
to the
equipment.
Insulating
measures
No fire
Saijo denki International co.,ltd.
7
If, in the course of carrying out repairs, it becomes absolutely necessary to check out the electrical parts
with the electrical parts box cover of one or more of the indoor units and the service panel of the outdoor
unit removed in order to find out exactly where the trouble lies, put a sign in place so that no-one will
approach the work location before proceeding with the work. Third-party individuals may enter the work site
and receive electric shocks if this warning is not heeded.
Connect the cut-off lead wires with crimp contact, etc., put the closed end side upward and then apply a
water-cut method, otherwise a leak or production of fire is caused at the users’ side.
When performing repairs using a gas burner, replace the refrigerant with nitrogen gas because the oil that
coats the pipes may otherwise burn.
When repairing the refrigerating cycle, take the following measures.
1) Be attentive to fire around the cycle. When using a gas stove, etc., be sure to put out fire before
work; otherwise the oil mixed with refrigerant gas may catch fire.
2) Do not use a welder in the closed room. When using it without ventilation, carbon monoxide
poisoning may be caused.
3) Do not bring inflammables close to the refrigerant cycle, otherwise fire of the welder
may catch the inflammables.
The refrigerant used by this air conditioner is the R410A.
Check the used refrigerant name and use tools and materials of the parts which match with it.
For the products which use R410A refrigerant, the refrigerant name is indicated at a position on the
outdoor unit where is easy to see. To prevent miss-charging, the route of the service port is changed from
one of the former R22.
Refrigerant
For an air conditioner which uses R410A, never use other refrigerant than R410A. For an air conditioner
which uses other refrigerant (R22, etc.), never use R410A.
If different types of refrigerant are mixed, abnormal high pressure generates in the refrigerating cycle
and an injury due to breakage may be caused.
When the air conditioner has been installed or relocated, follow the instructions in the Installation Manual
and urge the air completely so that no gases other than the refrigerant will be mixed in the refrigerating
cycle. Failure to purge the air completely may cause the air conditioner to malfunction.
When any of the electrical parts are to be replaced, ensure that the replacement parts satisfy the
specifications given in the Service Manual (or use the parts contained on the parts list in the Service
Manual).
Use of any parts which do not satisfy the required specifications may give rise to electric
shocks, smoking and/ or a fire.
Check earth
wires.
Before troubleshooting or repair work, check the earth wire is connected to the earth terminals of the main
unit, otherwise an electric shock is caused when a leak occurs.If the earth wire is not correctly connected,
contact an electric engineer for rework.
After completing the repair or relocation work, check that the ground wires are connected properly.
Be sure to connect earth wire. (Grounding work) Incomplete grounding causes an electric shock.
Do not connect ground wires to gas pipes, water pipes, and lightning rods or ground wires for telephone
wires.
Do not modify the products.Do not also disassemble or modify the parts.
It may cause a fire, electric shock or injury.